用MATLAB/Simulink对并联型有源电力滤波器进行仿真

Musa Yusup Lada, Ismadi Bugis, Md. Hairul Nizam Talib
{"title":"用MATLAB/Simulink对并联型有源电力滤波器进行仿真","authors":"Musa Yusup Lada, Ismadi Bugis, Md. Hairul Nizam Talib","doi":"10.1109/PEOCO.2010.5559218","DOIUrl":null,"url":null,"abstract":"Along with increasing demand on improving power quality, the most popular technique that has been used is Active Power Filter (APF); this is because APF can easily eliminate unwanted harmonics, improve power factor and overcome voltage sags. This paper will discuss and analyze the simulation result for a three-phase shunt active power filter using MATLAB/Simulink program. This simulation will implement a non-linear load and compensate line current harmonics under balance and unbalance load. As a result of the simulation, it is found that an active power filter is the better way to reduce the total harmonic distortion (THD) which is required by quality standards IEEE-519.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"35","resultStr":"{\"title\":\"Simulation a shunt active power filter using MATLAB/Simulink\",\"authors\":\"Musa Yusup Lada, Ismadi Bugis, Md. Hairul Nizam Talib\",\"doi\":\"10.1109/PEOCO.2010.5559218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Along with increasing demand on improving power quality, the most popular technique that has been used is Active Power Filter (APF); this is because APF can easily eliminate unwanted harmonics, improve power factor and overcome voltage sags. This paper will discuss and analyze the simulation result for a three-phase shunt active power filter using MATLAB/Simulink program. This simulation will implement a non-linear load and compensate line current harmonics under balance and unbalance load. As a result of the simulation, it is found that an active power filter is the better way to reduce the total harmonic distortion (THD) which is required by quality standards IEEE-519.\",\"PeriodicalId\":379868,\"journal\":{\"name\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"35\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 4th International Power Engineering and Optimization Conference (PEOCO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEOCO.2010.5559218\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 35

摘要

随着人们对改善电能质量的要求越来越高,目前最常用的技术是有源电力滤波器(APF);这是因为APF可以很容易地消除不必要的谐波,提高功率因数和克服电压下降。本文将利用MATLAB/Simulink程序对三相并联有源电力滤波器的仿真结果进行讨论和分析。该仿真将实现一个非线性负载,并补偿平衡和不平衡负载下的线路电流谐波。仿真结果表明,有源电力滤波器是降低IEEE-519质量标准要求的总谐波失真(THD)的较好方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulation a shunt active power filter using MATLAB/Simulink
Along with increasing demand on improving power quality, the most popular technique that has been used is Active Power Filter (APF); this is because APF can easily eliminate unwanted harmonics, improve power factor and overcome voltage sags. This paper will discuss and analyze the simulation result for a three-phase shunt active power filter using MATLAB/Simulink program. This simulation will implement a non-linear load and compensate line current harmonics under balance and unbalance load. As a result of the simulation, it is found that an active power filter is the better way to reduce the total harmonic distortion (THD) which is required by quality standards IEEE-519.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信