{"title":"单中性点不对称六相感应电机驱动系统健康与故障运行的vv- DTC","authors":"V. B. Melo, Gilielson F. da Paz, I. S. de Freitas","doi":"10.1109/COBEP53665.2021.9684138","DOIUrl":null,"url":null,"abstract":"This paper discusses a Direct Torque Control (DTC) strategy for an asymmetrical six-phase induction machine drive system that makes use of an isolated single neutral. By means of simulations, it is shown that the proposed method provides proper healthy and postfault operation when a single-phase open-circuit fault occurs. A natural fault-tolerance feature is observed, since the control algorithm does not need to be reconfigurated when the system migrates from healthy to postfault operation.","PeriodicalId":442384,"journal":{"name":"2021 Brazilian Power Electronics Conference (COBEP)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"vv- DTC for Healthy and Faulty Operation of an Asymmetrical Six - Phase Induction Machine Drive System With Single Neutral\",\"authors\":\"V. B. Melo, Gilielson F. da Paz, I. S. de Freitas\",\"doi\":\"10.1109/COBEP53665.2021.9684138\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses a Direct Torque Control (DTC) strategy for an asymmetrical six-phase induction machine drive system that makes use of an isolated single neutral. By means of simulations, it is shown that the proposed method provides proper healthy and postfault operation when a single-phase open-circuit fault occurs. A natural fault-tolerance feature is observed, since the control algorithm does not need to be reconfigurated when the system migrates from healthy to postfault operation.\",\"PeriodicalId\":442384,\"journal\":{\"name\":\"2021 Brazilian Power Electronics Conference (COBEP)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Brazilian Power Electronics Conference (COBEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COBEP53665.2021.9684138\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Brazilian Power Electronics Conference (COBEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COBEP53665.2021.9684138","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
vv- DTC for Healthy and Faulty Operation of an Asymmetrical Six - Phase Induction Machine Drive System With Single Neutral
This paper discusses a Direct Torque Control (DTC) strategy for an asymmetrical six-phase induction machine drive system that makes use of an isolated single neutral. By means of simulations, it is shown that the proposed method provides proper healthy and postfault operation when a single-phase open-circuit fault occurs. A natural fault-tolerance feature is observed, since the control algorithm does not need to be reconfigurated when the system migrates from healthy to postfault operation.