温度瞬变对油纸样品频域介电响应的影响

Ankita Garg, C. Banerjee, A. Baral, S. Chakravorti
{"title":"温度瞬变对油纸样品频域介电响应的影响","authors":"Ankita Garg, C. Banerjee, A. Baral, S. Chakravorti","doi":"10.1109/catcon52335.2021.9670487","DOIUrl":null,"url":null,"abstract":"The health of the oil paper insulation of a transformer can be monitored by using a dielectric testing technique well-known as Frequency domain spectroscopy (FDS). The insulation response profile obtained from FDS test is influenced by measurement temperature. The time required by dielectric to reach thermal equilibrium is long. Therefore, it is possible that FDS tests are conducted during temperature transient conditions. This may affect the FDS profile and corresponding analysis. This paper focuses on the laboratory experiments carried out on oil-paper sample to analyze the effect of temperature transients on the FDS measurement profile. To compensate this effect of transients on FDS profile, a methodology is proposed further in this paper (on a sample).","PeriodicalId":162130,"journal":{"name":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Temperature Transient on Frequency Domain Dielectric Response of Oil-Paper Sample\",\"authors\":\"Ankita Garg, C. Banerjee, A. Baral, S. Chakravorti\",\"doi\":\"10.1109/catcon52335.2021.9670487\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The health of the oil paper insulation of a transformer can be monitored by using a dielectric testing technique well-known as Frequency domain spectroscopy (FDS). The insulation response profile obtained from FDS test is influenced by measurement temperature. The time required by dielectric to reach thermal equilibrium is long. Therefore, it is possible that FDS tests are conducted during temperature transient conditions. This may affect the FDS profile and corresponding analysis. This paper focuses on the laboratory experiments carried out on oil-paper sample to analyze the effect of temperature transients on the FDS measurement profile. To compensate this effect of transients on FDS profile, a methodology is proposed further in this paper (on a sample).\",\"PeriodicalId\":162130,\"journal\":{\"name\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/catcon52335.2021.9670487\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/catcon52335.2021.9670487","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

变压器油纸绝缘的健康状况可以通过一种被称为频域光谱(FDS)的介电测试技术来监测。FDS试验得到的绝缘响应曲线受测量温度的影响。电介质达到热平衡所需的时间很长。因此,FDS试验有可能在温度瞬态条件下进行。这可能会影响FDS配置文件和相应的分析。本文通过油纸样品的室内实验,分析了温度瞬变对FDS测量曲线的影响。为了补偿瞬态对FDS曲线的影响,本文进一步提出了一种方法(基于样本)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of Temperature Transient on Frequency Domain Dielectric Response of Oil-Paper Sample
The health of the oil paper insulation of a transformer can be monitored by using a dielectric testing technique well-known as Frequency domain spectroscopy (FDS). The insulation response profile obtained from FDS test is influenced by measurement temperature. The time required by dielectric to reach thermal equilibrium is long. Therefore, it is possible that FDS tests are conducted during temperature transient conditions. This may affect the FDS profile and corresponding analysis. This paper focuses on the laboratory experiments carried out on oil-paper sample to analyze the effect of temperature transients on the FDS measurement profile. To compensate this effect of transients on FDS profile, a methodology is proposed further in this paper (on a sample).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信