{"title":"煤矿井下传送带远程监控的几点考虑","authors":"R. Munz","doi":"10.1109/IAS.1988.25219","DOIUrl":null,"url":null,"abstract":"The author presents typical electrical circuits that can be used to interface a minewide monitoring system with coal-mine conveyor-belt control circuits. Some considerations and justifications for monitoring and for remotely controlling conveyors are presented. The basic conveyor control circuit in common use is presented and discussed.<<ETX>>","PeriodicalId":274766,"journal":{"name":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","volume":"155 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Considerations for remotely monitoring and controlling conveyor belts in underground coal mines\",\"authors\":\"R. Munz\",\"doi\":\"10.1109/IAS.1988.25219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The author presents typical electrical circuits that can be used to interface a minewide monitoring system with coal-mine conveyor-belt control circuits. Some considerations and justifications for monitoring and for remotely controlling conveyors are presented. The basic conveyor control circuit in common use is presented and discussed.<<ETX>>\",\"PeriodicalId\":274766,\"journal\":{\"name\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"155 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1988.25219\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1988.25219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Considerations for remotely monitoring and controlling conveyor belts in underground coal mines
The author presents typical electrical circuits that can be used to interface a minewide monitoring system with coal-mine conveyor-belt control circuits. Some considerations and justifications for monitoring and for remotely controlling conveyors are presented. The basic conveyor control circuit in common use is presented and discussed.<>