使用部分已知的校准负载确定六端口反射计的匹配负载响应

K. Staszek
{"title":"使用部分已知的校准负载确定六端口反射计的匹配负载响应","authors":"K. Staszek","doi":"10.23919/URSI48707.2020.9253760","DOIUrl":null,"url":null,"abstract":"This paper presents a method for determining a six-port reflectometer's response to a matched load with the use of partially known calibration loads. It utilizes nine calibration loads which can be of unknown magnitude and phase, however, three of them must exhibit magnitudes possibly close to each other with a reasonable phase separation. The algorithm was tested with the use of an exemplary broadband six-port reflectometer operating over the frequency range from 2.5 GHz to 3.5 GHz. The power values obtained using the proposed method are very close to those directly measured by the six-port reflectometer with a broadband matched load from precision calibration kit connected as DUT.","PeriodicalId":185201,"journal":{"name":"2020 Baltic URSI Symposium (URSI)","volume":"120 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determining a Matched Load Response of Six-Port Reflectometer Using Partially Known Calibration Loads\",\"authors\":\"K. Staszek\",\"doi\":\"10.23919/URSI48707.2020.9253760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a method for determining a six-port reflectometer's response to a matched load with the use of partially known calibration loads. It utilizes nine calibration loads which can be of unknown magnitude and phase, however, three of them must exhibit magnitudes possibly close to each other with a reasonable phase separation. The algorithm was tested with the use of an exemplary broadband six-port reflectometer operating over the frequency range from 2.5 GHz to 3.5 GHz. The power values obtained using the proposed method are very close to those directly measured by the six-port reflectometer with a broadband matched load from precision calibration kit connected as DUT.\",\"PeriodicalId\":185201,\"journal\":{\"name\":\"2020 Baltic URSI Symposium (URSI)\",\"volume\":\"120 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Baltic URSI Symposium (URSI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/URSI48707.2020.9253760\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Baltic URSI Symposium (URSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/URSI48707.2020.9253760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种利用部分已知的校准载荷来确定六端口反射计对匹配载荷的响应的方法。它使用了9个未知大小和相位的校准负载,但是,其中3个必须具有合理的相位分离,且大小可能彼此接近。该算法使用示范性宽带六端口反射计进行了测试,工作频率范围为2.5 GHz至3.5 GHz。用该方法得到的功率值与连接在DUT上的带宽带匹配负载的六端口反射计直接测量的功率值非常接近。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determining a Matched Load Response of Six-Port Reflectometer Using Partially Known Calibration Loads
This paper presents a method for determining a six-port reflectometer's response to a matched load with the use of partially known calibration loads. It utilizes nine calibration loads which can be of unknown magnitude and phase, however, three of them must exhibit magnitudes possibly close to each other with a reasonable phase separation. The algorithm was tested with the use of an exemplary broadband six-port reflectometer operating over the frequency range from 2.5 GHz to 3.5 GHz. The power values obtained using the proposed method are very close to those directly measured by the six-port reflectometer with a broadband matched load from precision calibration kit connected as DUT.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信