用于振动声学的线性阵列换能器

G.T. Silva, F. Mostafa
{"title":"用于振动声学的线性阵列换能器","authors":"G.T. Silva, F. Mostafa","doi":"10.1109/ULTSYM.2002.1193481","DOIUrl":null,"url":null,"abstract":"In this work, we present computational simulations of the beamforming in transducers with two linear arrays for vibro-acoustography. The simulation will be used as the basis of linear array design for vibro-acoustography imaging. The point spread function (PSF) of the system defined as the stress field at the focal zone, is obtained as the product of the spatial impulse functions of the arrays. Grating lobe effects in the stress field are analyzed. Results show that a transverse resolution of about (2/spl times/3) mm, with proper grating lobe suppression, can be achieved by using two 32-element arrays. Furthermore, the variations on the PSF of the vibro-acoustography system based on linear arrays are reasonably acceptable for medical imaging applications.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"139 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Linear array transducers for vibro-acoustography\",\"authors\":\"G.T. Silva, F. Mostafa\",\"doi\":\"10.1109/ULTSYM.2002.1193481\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, we present computational simulations of the beamforming in transducers with two linear arrays for vibro-acoustography. The simulation will be used as the basis of linear array design for vibro-acoustography imaging. The point spread function (PSF) of the system defined as the stress field at the focal zone, is obtained as the product of the spatial impulse functions of the arrays. Grating lobe effects in the stress field are analyzed. Results show that a transverse resolution of about (2/spl times/3) mm, with proper grating lobe suppression, can be achieved by using two 32-element arrays. Furthermore, the variations on the PSF of the vibro-acoustography system based on linear arrays are reasonably acceptable for medical imaging applications.\",\"PeriodicalId\":378705,\"journal\":{\"name\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"volume\":\"139 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2002.1193481\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1193481","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在这项工作中,我们提出了两个线性阵列用于振动声谱的换能器的波束形成的计算模拟。仿真结果可作为振声成像线性阵列设计的基础。系统的点扩展函数(PSF)定义为焦点区域的应力场,它是阵列空间脉冲函数的乘积。分析了应力场中光栅瓣效应。结果表明,在适当抑制光栅瓣的情况下,采用两个32元阵列可以获得约(2/spl × /3) mm的横向分辨率。此外,基于线性阵列的振声成像系统的PSF变化对于医学成像应用是合理可接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Linear array transducers for vibro-acoustography
In this work, we present computational simulations of the beamforming in transducers with two linear arrays for vibro-acoustography. The simulation will be used as the basis of linear array design for vibro-acoustography imaging. The point spread function (PSF) of the system defined as the stress field at the focal zone, is obtained as the product of the spatial impulse functions of the arrays. Grating lobe effects in the stress field are analyzed. Results show that a transverse resolution of about (2/spl times/3) mm, with proper grating lobe suppression, can be achieved by using two 32-element arrays. Furthermore, the variations on the PSF of the vibro-acoustography system based on linear arrays are reasonably acceptable for medical imaging applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信