土壤/沉积物中六价铬制备和分析的技术保温时间评价

R. Vitale, G. R. Mussoline, K. A. Rinehimer, Karen L. Moeser, J. C. Petura
{"title":"土壤/沉积物中六价铬制备和分析的技术保温时间评价","authors":"R. Vitale, G. R. Mussoline, K. A. Rinehimer, Karen L. Moeser, J. C. Petura","doi":"10.1080/10588330091134248","DOIUrl":null,"url":null,"abstract":"Chromium (Cr) is routinely measured during environmental investigations involving soils and other solid matrix sampling. Regulatory-approved analytical methods are available to extract and quantify total Cr in various environmental media. However, due to significant toxicity differences between trivalent [Cr(III)] and hexavalent [Cr(VI)] valences, it is compelling that the two can be quantitatively distinguished. SW-846 Method 3060A is an effective extraction technique for soluble and insoluble Cr(VI). Several regulatory-approved methods exist for quantitating the Cr(VI) in extracts or aqueous samples. Although a 6-month holding time for total Cr is not encumbering, investigators are challenged by the typical 24-h holding time (sample collection through analysis) for Cr(VI) in aqueous samples and the 24- to 96-h holding time range for solid matrix samples typically set by regulators. This research report addresses quantitating Cr(VI) in solid matrices. Using SW-846 Methods 3060A/7196A, a scientifically defensible basis has been established for designating a 30-day holding time for Cr(VI) extraction from solid matrices and a 7-day holding time for Cr(VI) analysis once solubilized in the alkaline digestate. The study results indicate that a 30-day holding time, from sample collection to preparation, and a 7-day holding time, from digestion to analysis, are appropriate for Cr(VI) analysis.","PeriodicalId":433778,"journal":{"name":"Journal of Soil Contamination","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"An Evaluation of a Technical Holding Time for the Preparation and Analysis of Hexavalent Chromium in Soils/Sediments\",\"authors\":\"R. Vitale, G. R. Mussoline, K. A. Rinehimer, Karen L. Moeser, J. C. Petura\",\"doi\":\"10.1080/10588330091134248\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Chromium (Cr) is routinely measured during environmental investigations involving soils and other solid matrix sampling. Regulatory-approved analytical methods are available to extract and quantify total Cr in various environmental media. However, due to significant toxicity differences between trivalent [Cr(III)] and hexavalent [Cr(VI)] valences, it is compelling that the two can be quantitatively distinguished. SW-846 Method 3060A is an effective extraction technique for soluble and insoluble Cr(VI). Several regulatory-approved methods exist for quantitating the Cr(VI) in extracts or aqueous samples. Although a 6-month holding time for total Cr is not encumbering, investigators are challenged by the typical 24-h holding time (sample collection through analysis) for Cr(VI) in aqueous samples and the 24- to 96-h holding time range for solid matrix samples typically set by regulators. This research report addresses quantitating Cr(VI) in solid matrices. Using SW-846 Methods 3060A/7196A, a scientifically defensible basis has been established for designating a 30-day holding time for Cr(VI) extraction from solid matrices and a 7-day holding time for Cr(VI) analysis once solubilized in the alkaline digestate. The study results indicate that a 30-day holding time, from sample collection to preparation, and a 7-day holding time, from digestion to analysis, are appropriate for Cr(VI) analysis.\",\"PeriodicalId\":433778,\"journal\":{\"name\":\"Journal of Soil Contamination\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Soil Contamination\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10588330091134248\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Soil Contamination","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10588330091134248","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在涉及土壤和其他固体基质采样的环境调查中,铬(Cr)是常规测量。监管机构批准的分析方法可用于提取和量化各种环境介质中的总铬。然而,由于三价[Cr(III)]和六价[Cr(VI)]之间的毒性存在显著差异,因此有必要对两者进行定量区分。方法3060A是一种有效的可溶性和不溶性铬(VI)的提取技术。有几种经监管部门批准的方法可用于定量提取液或水样中的铬(VI)。虽然6个月的总Cr保持时间不会妨碍研究人员,但水样品中Cr(VI)的典型24小时保持时间(通过分析收集样品)和固体基质样品的24至96小时保持时间范围通常由监管机构设定。本研究报告讨论了固体基质中Cr(VI)的定量测定。采用SW-846方法3060A/7196A,确定了从固体基质中提取Cr(VI)的保存时间为30天,在碱性消化液中溶解Cr(VI)后分析Cr(VI)的保存时间为7天。研究结果表明,从样品采集到制备的保温时间为30天,从消化到分析的保温时间为7天,对Cr(VI)进行分析比较合适。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Evaluation of a Technical Holding Time for the Preparation and Analysis of Hexavalent Chromium in Soils/Sediments
Chromium (Cr) is routinely measured during environmental investigations involving soils and other solid matrix sampling. Regulatory-approved analytical methods are available to extract and quantify total Cr in various environmental media. However, due to significant toxicity differences between trivalent [Cr(III)] and hexavalent [Cr(VI)] valences, it is compelling that the two can be quantitatively distinguished. SW-846 Method 3060A is an effective extraction technique for soluble and insoluble Cr(VI). Several regulatory-approved methods exist for quantitating the Cr(VI) in extracts or aqueous samples. Although a 6-month holding time for total Cr is not encumbering, investigators are challenged by the typical 24-h holding time (sample collection through analysis) for Cr(VI) in aqueous samples and the 24- to 96-h holding time range for solid matrix samples typically set by regulators. This research report addresses quantitating Cr(VI) in solid matrices. Using SW-846 Methods 3060A/7196A, a scientifically defensible basis has been established for designating a 30-day holding time for Cr(VI) extraction from solid matrices and a 7-day holding time for Cr(VI) analysis once solubilized in the alkaline digestate. The study results indicate that a 30-day holding time, from sample collection to preparation, and a 7-day holding time, from digestion to analysis, are appropriate for Cr(VI) analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信