纺粘塑料薄膜的水蒸气转移性能

A. Janssens, H. Hens
{"title":"纺粘塑料薄膜的水蒸气转移性能","authors":"A. Janssens, H. Hens","doi":"10.1177/109719639702100209","DOIUrl":null,"url":null,"abstract":"The water vapour permeances of two types of spunbonded plastic roofunderlay films are measured using different methods. Experiments with isother mal permeance cup procedures are discussed. Because of the high permeance of the tested films, the analysis of these measurements is not as simple as described in most standards. To obtain reliable results of the cup tests, the influence of the water vapour diffusion resistance of the air films is separately investigated. A non-isothermal per meance test was developed to measure the effect of surface condensation on the va pour permeance of the films. The paper describes the apparatus and discusses the re liability of the method. The properties measured by the non-isothermal test method are compared to those obtained with the isothermal method.","PeriodicalId":435154,"journal":{"name":"Journal of Thermal Envelope and Building Science","volume":"2016 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Water Vapour Transfer Properties of Spunbonded Plastic Films\",\"authors\":\"A. Janssens, H. Hens\",\"doi\":\"10.1177/109719639702100209\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The water vapour permeances of two types of spunbonded plastic roofunderlay films are measured using different methods. Experiments with isother mal permeance cup procedures are discussed. Because of the high permeance of the tested films, the analysis of these measurements is not as simple as described in most standards. To obtain reliable results of the cup tests, the influence of the water vapour diffusion resistance of the air films is separately investigated. A non-isothermal per meance test was developed to measure the effect of surface condensation on the va pour permeance of the films. The paper describes the apparatus and discusses the re liability of the method. The properties measured by the non-isothermal test method are compared to those obtained with the isothermal method.\",\"PeriodicalId\":435154,\"journal\":{\"name\":\"Journal of Thermal Envelope and Building Science\",\"volume\":\"2016 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Envelope and Building Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/109719639702100209\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Envelope and Building Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/109719639702100209","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

采用不同的方法测量了两种纺粘塑料屋面衬垫膜的水蒸气渗透率。讨论了等渗杯程序的实验。由于被测薄膜的高渗透率,这些测量的分析并不像大多数标准中描述的那样简单。为了得到可靠的杯形试验结果,分别研究了空气膜的水蒸气扩散阻力对杯形试验的影响。开发了一种非等温平均试验,以测量表面凝结对膜的渗透性的影响。本文介绍了该装置,并讨论了该方法的可靠性。用非等温法测得的性能与等温法测得的性能进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Water Vapour Transfer Properties of Spunbonded Plastic Films
The water vapour permeances of two types of spunbonded plastic roofunderlay films are measured using different methods. Experiments with isother mal permeance cup procedures are discussed. Because of the high permeance of the tested films, the analysis of these measurements is not as simple as described in most standards. To obtain reliable results of the cup tests, the influence of the water vapour diffusion resistance of the air films is separately investigated. A non-isothermal per meance test was developed to measure the effect of surface condensation on the va pour permeance of the films. The paper describes the apparatus and discusses the re liability of the method. The properties measured by the non-isothermal test method are compared to those obtained with the isothermal method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信