{"title":"木聚糖1424螺柱的再利用研究","authors":"M. Ruffin","doi":"10.1115/pvp2019-93628","DOIUrl":null,"url":null,"abstract":"\n While there are many factors that should be considered when determining if a stud can be reused, one of them is the nut factor. The study described in this paper set out to determine if the nut factor of a Xylan 1424 coated stud is significantly affected by the age of the coating and/or the cycles of tightening. A load cell was used to compare the nut factor: 1) of previously installed (used) studs to new studs, 2) of a new and used stud that were tightened more than once, and 3) associated with the first tightening pass to subsequent passes for a new stud. The results show that the age of the stud and the amount it has been tightened contribute to an increased nut factor for used Xylan 1424 studs.","PeriodicalId":150804,"journal":{"name":"Volume 3: Design and Analysis","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Study on the Reuse of Xylan 1424 Studs\",\"authors\":\"M. Ruffin\",\"doi\":\"10.1115/pvp2019-93628\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n While there are many factors that should be considered when determining if a stud can be reused, one of them is the nut factor. The study described in this paper set out to determine if the nut factor of a Xylan 1424 coated stud is significantly affected by the age of the coating and/or the cycles of tightening. A load cell was used to compare the nut factor: 1) of previously installed (used) studs to new studs, 2) of a new and used stud that were tightened more than once, and 3) associated with the first tightening pass to subsequent passes for a new stud. The results show that the age of the stud and the amount it has been tightened contribute to an increased nut factor for used Xylan 1424 studs.\",\"PeriodicalId\":150804,\"journal\":{\"name\":\"Volume 3: Design and Analysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3: Design and Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/pvp2019-93628\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Design and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/pvp2019-93628","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
While there are many factors that should be considered when determining if a stud can be reused, one of them is the nut factor. The study described in this paper set out to determine if the nut factor of a Xylan 1424 coated stud is significantly affected by the age of the coating and/or the cycles of tightening. A load cell was used to compare the nut factor: 1) of previously installed (used) studs to new studs, 2) of a new and used stud that were tightened more than once, and 3) associated with the first tightening pass to subsequent passes for a new stud. The results show that the age of the stud and the amount it has been tightened contribute to an increased nut factor for used Xylan 1424 studs.