{"title":"神经外科患者视神经鞘直径与直接颅内压测量的关系","authors":"B. Kc, Amit Thapa","doi":"10.3126/jkmc.v11i2.48671","DOIUrl":null,"url":null,"abstract":"Background: Invasive intracranial devices are gold standard for measurement of intracranial pressure (ICP), however optic nerve sheath diameter (ONSD) by using ultrasound is emerging lately as a non-invasive bedside tool. Objectives: This study aimed to find association between ONSD and invasive ICP and also to find optimum cut off of ONSD to detect raised ICP. Methods: An analytical observational study using a convenience sample was done at Department of Neurosurgery, Kathmandu Medical College from March 1, 2022 and March 31, 2022. The ONSD of both the eyes were measured using ultrasound in patients with ventriculostomy catheter. Simultaneous ICP was also recorded. The Pearson’s correlation coefficient was used to assess an association between the ONSD and direct ICP measurement. Results: Total of 40 ONSD measurements were done in 12 neurosurgical patients. Age of patients ranged from 17-75 years with mean age of 47.33 ± 17.67 years with male to female ratio of 1:2 respectively. Pearson’s correlation coefficient of ONSD and invasive ICP was 0.86 (p-value <0.001) showing significant correlation. Receiver operator characteristic curve generated an area under the curve with value of 0.93 (95% of confidence interval = 0.86 to 1.00). The ONSD cut off value of >5 mm predicted ICP >20 mmHg with a sensitivity of 92.3% and specificity of 85.2%. Conclusion: There exists a significant correlation between ONSD and invasive ICP with optimal cut off >5 mm to detect raised ICP.","PeriodicalId":254049,"journal":{"name":"Journal of Kathmandu Medical College","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Association of optic nerve sheath diameter with direct intracranial pressure measurement in neurosurgical patients\",\"authors\":\"B. Kc, Amit Thapa\",\"doi\":\"10.3126/jkmc.v11i2.48671\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Invasive intracranial devices are gold standard for measurement of intracranial pressure (ICP), however optic nerve sheath diameter (ONSD) by using ultrasound is emerging lately as a non-invasive bedside tool. Objectives: This study aimed to find association between ONSD and invasive ICP and also to find optimum cut off of ONSD to detect raised ICP. Methods: An analytical observational study using a convenience sample was done at Department of Neurosurgery, Kathmandu Medical College from March 1, 2022 and March 31, 2022. The ONSD of both the eyes were measured using ultrasound in patients with ventriculostomy catheter. Simultaneous ICP was also recorded. The Pearson’s correlation coefficient was used to assess an association between the ONSD and direct ICP measurement. Results: Total of 40 ONSD measurements were done in 12 neurosurgical patients. Age of patients ranged from 17-75 years with mean age of 47.33 ± 17.67 years with male to female ratio of 1:2 respectively. Pearson’s correlation coefficient of ONSD and invasive ICP was 0.86 (p-value <0.001) showing significant correlation. Receiver operator characteristic curve generated an area under the curve with value of 0.93 (95% of confidence interval = 0.86 to 1.00). The ONSD cut off value of >5 mm predicted ICP >20 mmHg with a sensitivity of 92.3% and specificity of 85.2%. Conclusion: There exists a significant correlation between ONSD and invasive ICP with optimal cut off >5 mm to detect raised ICP.\",\"PeriodicalId\":254049,\"journal\":{\"name\":\"Journal of Kathmandu Medical College\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Kathmandu Medical College\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3126/jkmc.v11i2.48671\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Kathmandu Medical College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/jkmc.v11i2.48671","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:有创颅内压测量仪是测量颅内压(ICP)的金标准,然而视神经鞘直径(ONSD)的超声测量是最近出现的一种无创床边工具。目的:本研究旨在发现ONSD与侵入性ICP之间的关系,并寻找检测升高ICP的最佳ONSD截点。方法:于2022年3月1日至3月31日在加德满都医学院神经外科进行分析性观察研究,采用方便样本。采用超声测量脑室造瘘术患者双眼的ONSD。同时也记录了ICP。Pearson相关系数用于评估ONSD与直接ICP测量之间的关联。结果:12例神经外科患者共进行了40次ONSD测量。患者年龄17 ~ 75岁,平均年龄47.33±17.67岁,男女比例1:2。ONSD与侵入性ICP的Pearson相关系数为0.86 (p值5 mm预测ICP >20 mmHg),敏感性为92.3%,特异性为85.2%。结论:ONSD与有创性颅内压有显著相关性,最佳截距> 5mm检测颅内压升高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Association of optic nerve sheath diameter with direct intracranial pressure measurement in neurosurgical patients
Background: Invasive intracranial devices are gold standard for measurement of intracranial pressure (ICP), however optic nerve sheath diameter (ONSD) by using ultrasound is emerging lately as a non-invasive bedside tool. Objectives: This study aimed to find association between ONSD and invasive ICP and also to find optimum cut off of ONSD to detect raised ICP. Methods: An analytical observational study using a convenience sample was done at Department of Neurosurgery, Kathmandu Medical College from March 1, 2022 and March 31, 2022. The ONSD of both the eyes were measured using ultrasound in patients with ventriculostomy catheter. Simultaneous ICP was also recorded. The Pearson’s correlation coefficient was used to assess an association between the ONSD and direct ICP measurement. Results: Total of 40 ONSD measurements were done in 12 neurosurgical patients. Age of patients ranged from 17-75 years with mean age of 47.33 ± 17.67 years with male to female ratio of 1:2 respectively. Pearson’s correlation coefficient of ONSD and invasive ICP was 0.86 (p-value <0.001) showing significant correlation. Receiver operator characteristic curve generated an area under the curve with value of 0.93 (95% of confidence interval = 0.86 to 1.00). The ONSD cut off value of >5 mm predicted ICP >20 mmHg with a sensitivity of 92.3% and specificity of 85.2%. Conclusion: There exists a significant correlation between ONSD and invasive ICP with optimal cut off >5 mm to detect raised ICP.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信