污水处理厂的故障检测

I. Baklouti, M. Mansouri, H. Nounou, M. Slima, A. Hamida
{"title":"污水处理厂的故障检测","authors":"I. Baklouti, M. Mansouri, H. Nounou, M. Slima, A. Hamida","doi":"10.1109/ATSIP.2017.8075523","DOIUrl":null,"url":null,"abstract":"In this paper, Unscented Kalman filter (UKF) based Exponentially Weighted Moving Average (EWMA) is proposed for fault detection in a Wastewater Treatment Plant (WWTP). In the developed UKF-based EWMA, the UKF technique is used to compute the residual between the true and the estimated variable and the EWMA control chart is applied to detect the faults. The fault detection technique will be tested using simulated COST wastewater treatment ASM1 model. The detection results of the UKF-based EWMA technique are evaluated using three fault detection criteria: the false alarm rate (FAR), Average Run Length (ARL1) and the missed detection rate (MDR).","PeriodicalId":259951,"journal":{"name":"2017 International Conference on Advanced Technologies for Signal and Image Processing (ATSIP)","volume":"157 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Fault detection in a wastewater treatment plant\",\"authors\":\"I. Baklouti, M. Mansouri, H. Nounou, M. Slima, A. Hamida\",\"doi\":\"10.1109/ATSIP.2017.8075523\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, Unscented Kalman filter (UKF) based Exponentially Weighted Moving Average (EWMA) is proposed for fault detection in a Wastewater Treatment Plant (WWTP). In the developed UKF-based EWMA, the UKF technique is used to compute the residual between the true and the estimated variable and the EWMA control chart is applied to detect the faults. The fault detection technique will be tested using simulated COST wastewater treatment ASM1 model. The detection results of the UKF-based EWMA technique are evaluated using three fault detection criteria: the false alarm rate (FAR), Average Run Length (ARL1) and the missed detection rate (MDR).\",\"PeriodicalId\":259951,\"journal\":{\"name\":\"2017 International Conference on Advanced Technologies for Signal and Image Processing (ATSIP)\",\"volume\":\"157 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 International Conference on Advanced Technologies for Signal and Image Processing (ATSIP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ATSIP.2017.8075523\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Advanced Technologies for Signal and Image Processing (ATSIP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATSIP.2017.8075523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文提出了一种基于指数加权移动平均(EWMA)的无气味卡尔曼滤波(UKF)用于污水处理厂的故障检测。在基于UKF的EWMA中,利用UKF技术计算真实变量与估计变量之间的残差,并利用EWMA控制图进行故障检测。故障检测技术将使用模拟成本废水处理ASM1模型进行测试。采用虚警率(FAR)、平均运行长度(ARL1)和漏检率(MDR)三个故障检测标准对基于ukf的EWMA技术的检测结果进行了评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault detection in a wastewater treatment plant
In this paper, Unscented Kalman filter (UKF) based Exponentially Weighted Moving Average (EWMA) is proposed for fault detection in a Wastewater Treatment Plant (WWTP). In the developed UKF-based EWMA, the UKF technique is used to compute the residual between the true and the estimated variable and the EWMA control chart is applied to detect the faults. The fault detection technique will be tested using simulated COST wastewater treatment ASM1 model. The detection results of the UKF-based EWMA technique are evaluated using three fault detection criteria: the false alarm rate (FAR), Average Run Length (ARL1) and the missed detection rate (MDR).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信