双层防护涂层的耐蚀性研究

O. Totosko, P. Stukhlyak, Mytnyk Mykola, N. Dolgov, Roman Zolotiy, Danilo Stukhlyak
{"title":"双层防护涂层的耐蚀性研究","authors":"O. Totosko, P. Stukhlyak, Mytnyk Mykola, N. Dolgov, Roman Zolotiy, Danilo Stukhlyak","doi":"10.47459/cndcgs.2022.6","DOIUrl":null,"url":null,"abstract":"In this article, the influence of aggressive environments on a two-layer coating was investigated. Modern industry places high demands on quality control methods and coating properties during operation. It was established that the electrical resistance of epoxy composite samples depends significantly on the nature of the filler, the cohesive strength of the coatings, and the ambient temperature. We have determined the initial values of the volume resistance of epoxy composites and the temperature values when the samples lose their dielectric properties. The effectiveness of the use of electrospark water hammer treatment with the subsequent introduction of a bidisperse filler at optimal concentrations, which will increase the resist ance of protective coatings, is shown.","PeriodicalId":304895,"journal":{"name":"Challenges to national defence in contemporary geopolitical situation","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of Corrosion Resistance of Two-Layer Protective Coatings\",\"authors\":\"O. Totosko, P. Stukhlyak, Mytnyk Mykola, N. Dolgov, Roman Zolotiy, Danilo Stukhlyak\",\"doi\":\"10.47459/cndcgs.2022.6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, the influence of aggressive environments on a two-layer coating was investigated. Modern industry places high demands on quality control methods and coating properties during operation. It was established that the electrical resistance of epoxy composite samples depends significantly on the nature of the filler, the cohesive strength of the coatings, and the ambient temperature. We have determined the initial values of the volume resistance of epoxy composites and the temperature values when the samples lose their dielectric properties. The effectiveness of the use of electrospark water hammer treatment with the subsequent introduction of a bidisperse filler at optimal concentrations, which will increase the resist ance of protective coatings, is shown.\",\"PeriodicalId\":304895,\"journal\":{\"name\":\"Challenges to national defence in contemporary geopolitical situation\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Challenges to national defence in contemporary geopolitical situation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47459/cndcgs.2022.6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Challenges to national defence in contemporary geopolitical situation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47459/cndcgs.2022.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了侵蚀环境对双层涂层的影响。现代工业对生产过程中的质量控制方法和涂层性能提出了很高的要求。结果表明,环氧复合材料样品的电阻主要取决于填料的性质、涂层的粘结强度和环境温度。我们确定了环氧复合材料的初始体积电阻值和样品失去介电性能时的温量值。使用电火花水锤处理的有效性,随后在最佳浓度下引入双分散填料,这将增加保护涂层的抗蚀性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of Corrosion Resistance of Two-Layer Protective Coatings
In this article, the influence of aggressive environments on a two-layer coating was investigated. Modern industry places high demands on quality control methods and coating properties during operation. It was established that the electrical resistance of epoxy composite samples depends significantly on the nature of the filler, the cohesive strength of the coatings, and the ambient temperature. We have determined the initial values of the volume resistance of epoxy composites and the temperature values when the samples lose their dielectric properties. The effectiveness of the use of electrospark water hammer treatment with the subsequent introduction of a bidisperse filler at optimal concentrations, which will increase the resist ance of protective coatings, is shown.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信