输电线路横向参数对减小单极开孔二次弧电流的影响

M. E. Zevallos, M. Tavares
{"title":"输电线路横向参数对减小单极开孔二次弧电流的影响","authors":"M. E. Zevallos, M. Tavares","doi":"10.1109/TDC-LA.2010.5762943","DOIUrl":null,"url":null,"abstract":"A successful single-pole opening/reclosure procedure after single-phase faults in the EHV transmission lines requires parameters optimization for each transmission system. This paper shows the influence of transmission line transverse parameters together with reactive shunt compensation parameters in the reduction of secondary arc current after single-pole opening procedure for non-permanents faults. It is proposed a method to reduce the mutual coupling between phases in a three-phase system representation at fundamental frequency. Some simulations of transient overvoltage for different cases with optimized neutral reactors were performed with the ATP program.","PeriodicalId":222318,"journal":{"name":"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of transmission line transverse parameters in reduction secondary arc current during single-pole opening procedure\",\"authors\":\"M. E. Zevallos, M. Tavares\",\"doi\":\"10.1109/TDC-LA.2010.5762943\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A successful single-pole opening/reclosure procedure after single-phase faults in the EHV transmission lines requires parameters optimization for each transmission system. This paper shows the influence of transmission line transverse parameters together with reactive shunt compensation parameters in the reduction of secondary arc current after single-pole opening procedure for non-permanents faults. It is proposed a method to reduce the mutual coupling between phases in a three-phase system representation at fundamental frequency. Some simulations of transient overvoltage for different cases with optimized neutral reactors were performed with the ATP program.\",\"PeriodicalId\":222318,\"journal\":{\"name\":\"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)\",\"volume\":\"72 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC-LA.2010.5762943\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC-LA.2010.5762943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

超高压输电线路单相故障后成功的单极开/重合闸程序需要对每个输电系统进行参数优化。介绍了非永久性故障单极开断后,输电线路横向参数和无功并联补偿参数对降低二次弧电流的影响。提出了一种减少三相系统基频表示中相间相互耦合的方法。利用ATP程序对优化后的中性电抗器在不同情况下的瞬态过电压进行了模拟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of transmission line transverse parameters in reduction secondary arc current during single-pole opening procedure
A successful single-pole opening/reclosure procedure after single-phase faults in the EHV transmission lines requires parameters optimization for each transmission system. This paper shows the influence of transmission line transverse parameters together with reactive shunt compensation parameters in the reduction of secondary arc current after single-pole opening procedure for non-permanents faults. It is proposed a method to reduce the mutual coupling between phases in a three-phase system representation at fundamental frequency. Some simulations of transient overvoltage for different cases with optimized neutral reactors were performed with the ATP program.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信