K. Sheng, J. Cai, B. Libby, S. Benedict
{"title":"放射治疗中的肺部成像:4D与多模态的结合","authors":"K. Sheng,&nbsp;J. Cai,&nbsp;B. Libby,&nbsp;S. Benedict","doi":"10.1111/j.1617-0830.2008.00117.x","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The increasing research and clinical interest in the intrafractional motion management of lung tumour radiation treatment is in part fuelled by the availability of multiple 4D modalities that resolve temporal information of the tumour motion. These improved imaging modalities allow the escalation of dose to the tumour besides enhancing the conformality of the dose to a moving tumour, which could improve the local control rate. Magnetic resonance imaging (MRI; including dynamic MRI and hyperpolarized <sup>3</sup>He tagging), 4DCT, fluoroscopy and EM transponders are reviewed in this article. The working mechanisms, advantages/disadvantages and unique information of these techniques and their contribution to the management of lung cancer are discussed.</p>\n </div>","PeriodicalId":89151,"journal":{"name":"Imaging decisions (Berlin, Germany)","volume":"12 1","pages":"25-31"},"PeriodicalIF":0.0000,"publicationDate":"2008-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1617-0830.2008.00117.x","citationCount":"0","resultStr":"{\"title\":\"Imaging the Lung in Radiotherapy: Where 4D Meets Multimodality\",\"authors\":\"K. Sheng,&nbsp;J. Cai,&nbsp;B. Libby,&nbsp;S. Benedict\",\"doi\":\"10.1111/j.1617-0830.2008.00117.x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>The increasing research and clinical interest in the intrafractional motion management of lung tumour radiation treatment is in part fuelled by the availability of multiple 4D modalities that resolve temporal information of the tumour motion. These improved imaging modalities allow the escalation of dose to the tumour besides enhancing the conformality of the dose to a moving tumour, which could improve the local control rate. Magnetic resonance imaging (MRI; including dynamic MRI and hyperpolarized <sup>3</sup>He tagging), 4DCT, fluoroscopy and EM transponders are reviewed in this article. The working mechanisms, advantages/disadvantages and unique information of these techniques and their contribution to the management of lung cancer are discussed.</p>\\n </div>\",\"PeriodicalId\":89151,\"journal\":{\"name\":\"Imaging decisions (Berlin, Germany)\",\"volume\":\"12 1\",\"pages\":\"25-31\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1111/j.1617-0830.2008.00117.x\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Imaging decisions (Berlin, Germany)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/j.1617-0830.2008.00117.x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging decisions (Berlin, Germany)","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/j.1617-0830.2008.00117.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

越来越多的研究和临床对肺肿瘤放射治疗的病灶内运动管理的兴趣部分是由多种4D模式的可用性推动的,这些模式可以解决肿瘤运动的时间信息。这些改进的成像方式除了增强对移动肿瘤的剂量一致性外,还允许对肿瘤的剂量增加,这可以提高局部控制率。磁共振成像(MRI;包括动态MRI和超极化(he标记),dct,透视和EM转发器。讨论了这些技术的工作机制、优缺点、独特信息及其对肺癌治疗的贡献。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Imaging the Lung in Radiotherapy: Where 4D Meets Multimodality

The increasing research and clinical interest in the intrafractional motion management of lung tumour radiation treatment is in part fuelled by the availability of multiple 4D modalities that resolve temporal information of the tumour motion. These improved imaging modalities allow the escalation of dose to the tumour besides enhancing the conformality of the dose to a moving tumour, which could improve the local control rate. Magnetic resonance imaging (MRI; including dynamic MRI and hyperpolarized 3He tagging), 4DCT, fluoroscopy and EM transponders are reviewed in this article. The working mechanisms, advantages/disadvantages and unique information of these techniques and their contribution to the management of lung cancer are discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信