I. Kawaguchi, H. Ikeda, J. Kitano, Y. Ogihara, Miyokazu Syogaki, H. Morita
{"title":"一种新型的由逆变旁路电路组成的有源滤波系统,用于抑制山梨县磁悬浮试验线的谐波谐振","authors":"I. Kawaguchi, H. Ikeda, J. Kitano, Y. Ogihara, Miyokazu Syogaki, H. Morita","doi":"10.1109/PCCON.1997.645607","DOIUrl":null,"url":null,"abstract":"The authors have developed and proposed a novel active filter system composed of an inverter bypass circuit for the suppression of harmonic resonance conditions caused between the inductance behind the load bus and the capacitance of VAr equipment, especially at lower harmonic frequencies. They have installed this new harmonic compensation system in combination with TCR-type SVC and shunt LC filters at the Yamanashi Maglev test line. Here, they describe the outline of the reactive power and harmonic compensation systems, and harmonic resonance test results which show satisfactory performance of the active filter.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Novel active filter system composed of inverter bypass circuit for suppression of harmonic resonance at the Yamanashi Maglev test line\",\"authors\":\"I. Kawaguchi, H. Ikeda, J. Kitano, Y. Ogihara, Miyokazu Syogaki, H. Morita\",\"doi\":\"10.1109/PCCON.1997.645607\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors have developed and proposed a novel active filter system composed of an inverter bypass circuit for the suppression of harmonic resonance conditions caused between the inductance behind the load bus and the capacitance of VAr equipment, especially at lower harmonic frequencies. They have installed this new harmonic compensation system in combination with TCR-type SVC and shunt LC filters at the Yamanashi Maglev test line. Here, they describe the outline of the reactive power and harmonic compensation systems, and harmonic resonance test results which show satisfactory performance of the active filter.\",\"PeriodicalId\":262154,\"journal\":{\"name\":\"Proceedings of Power Conversion Conference - PCC '97\",\"volume\":\"69 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-08-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Power Conversion Conference - PCC '97\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCCON.1997.645607\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Power Conversion Conference - PCC '97","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCCON.1997.645607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Novel active filter system composed of inverter bypass circuit for suppression of harmonic resonance at the Yamanashi Maglev test line
The authors have developed and proposed a novel active filter system composed of an inverter bypass circuit for the suppression of harmonic resonance conditions caused between the inductance behind the load bus and the capacitance of VAr equipment, especially at lower harmonic frequencies. They have installed this new harmonic compensation system in combination with TCR-type SVC and shunt LC filters at the Yamanashi Maglev test line. Here, they describe the outline of the reactive power and harmonic compensation systems, and harmonic resonance test results which show satisfactory performance of the active filter.