低至高度近视的视野缺陷

Rab’ie Rusdi, Mohd Zaki Awg Isa
{"title":"低至高度近视的视野缺陷","authors":"Rab’ie Rusdi, Mohd Zaki Awg Isa","doi":"10.57002/jms.v18i1.244","DOIUrl":null,"url":null,"abstract":"Myopia is a global issue and significantly contributed to vision loss and ocular complications affected more than 1 billion people worldwide. This study aimed to evaluate visual field defects in association with the level of myopia degree. A retrospective study was conducted at MSU Eye Centre where the data of OCULUS Twinfield® 2 test from May 2015 to April 2018 were analysed. The global indices (mean deviation, MD, pattern standard deviation, PSD and probability plots) and spherical equivalent were used as parameters of this study. A total of 90 records comprising of 44.4% (40) of males and 55.6% (50) females with the mean age of 29.16 (SD: 10.27) years old and the spherical equivalent was -2.92 (SD:2.94) of the emmetrope, moderate and high myopia. The mean MD index was -1.71 dB (SD 3.95 dB) and PSD was 1.81 dB (SD:1.82 dB) respectively. There is a significant difference between emmetrope, moderate and high myope of MD (X2(2)=8.892, p=0.012) and PSD (X2(2) =42.057, p<0.01). The probability plot shows a significant difference for all quadrant (p<0.01) in P>2%. However, there was only a significant difference noted in temporal (X2(2)=9.47, p<0.01), nasal (X2(2)=11.33, p<0.01) and inferior (X2(2)=11.89, p<0.01) for P<1% probability plots. Pearson correlation test revealed a weak correlation for MD (rs= 0.253) and better correlation for PSD (rs= -0.703) in respective to spherical equivalent. Conclusions: There are localised visual field defect found in a higher degree of myopia, and therefore the visual field test is recommended in moderate to high myopic individuals for monitoring the myopia progression","PeriodicalId":340986,"journal":{"name":"Journal of Management &amp; Science","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual Field Defects in Low to High Myopia\",\"authors\":\"Rab’ie Rusdi, Mohd Zaki Awg Isa\",\"doi\":\"10.57002/jms.v18i1.244\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Myopia is a global issue and significantly contributed to vision loss and ocular complications affected more than 1 billion people worldwide. This study aimed to evaluate visual field defects in association with the level of myopia degree. A retrospective study was conducted at MSU Eye Centre where the data of OCULUS Twinfield® 2 test from May 2015 to April 2018 were analysed. The global indices (mean deviation, MD, pattern standard deviation, PSD and probability plots) and spherical equivalent were used as parameters of this study. A total of 90 records comprising of 44.4% (40) of males and 55.6% (50) females with the mean age of 29.16 (SD: 10.27) years old and the spherical equivalent was -2.92 (SD:2.94) of the emmetrope, moderate and high myopia. The mean MD index was -1.71 dB (SD 3.95 dB) and PSD was 1.81 dB (SD:1.82 dB) respectively. There is a significant difference between emmetrope, moderate and high myope of MD (X2(2)=8.892, p=0.012) and PSD (X2(2) =42.057, p<0.01). The probability plot shows a significant difference for all quadrant (p<0.01) in P>2%. However, there was only a significant difference noted in temporal (X2(2)=9.47, p<0.01), nasal (X2(2)=11.33, p<0.01) and inferior (X2(2)=11.89, p<0.01) for P<1% probability plots. Pearson correlation test revealed a weak correlation for MD (rs= 0.253) and better correlation for PSD (rs= -0.703) in respective to spherical equivalent. Conclusions: There are localised visual field defect found in a higher degree of myopia, and therefore the visual field test is recommended in moderate to high myopic individuals for monitoring the myopia progression\",\"PeriodicalId\":340986,\"journal\":{\"name\":\"Journal of Management &amp; Science\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Management &amp; Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.57002/jms.v18i1.244\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Management &amp; Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.57002/jms.v18i1.244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

近视是一个全球性的问题,是造成视力丧失和眼部并发症的重要原因,全世界有超过10亿人受到影响。本研究旨在评价视野缺损与近视程度的关系。在MSU眼科中心进行了一项回顾性研究,分析了2015年5月至2018年4月的OCULUS Twinfield®2测试数据。采用全局指数(平均偏差、MD、模式标准差、PSD和概率图)和球面等效系数作为本研究的参数。共90例,其中男性占44.4%(40例),女性占55.6%(50例),平均年龄29.16岁(SD: 10.27),近视、中、高度近视的球形当量为-2.92 (SD:2.94)。平均MD指数为-1.71 dB (SD: 3.95 dB), PSD指数为1.81 dB (SD:1.82 dB)。中度、高度近视的MD (X2(2)=8.892, p=0.012)与PSD (X2(2)= 42.057, p= 2%)之间差异有统计学意义。在p< 1%的概率图中,只有颞部(X2(2)=9.47, p<0.01)、鼻部(X2(2)=11.33, p<0.01)和下颌骨(X2(2)=11.89, p<0.01)有显著差异。Pearson相关检验显示,MD与球当量的相关性较弱(rs= 0.253), PSD与球当量的相关性较好(rs= -0.703)。结论:高度近视患者存在局部性视野缺损,建议中、高度近视患者进行视野检查,监测近视进展
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Visual Field Defects in Low to High Myopia
Myopia is a global issue and significantly contributed to vision loss and ocular complications affected more than 1 billion people worldwide. This study aimed to evaluate visual field defects in association with the level of myopia degree. A retrospective study was conducted at MSU Eye Centre where the data of OCULUS Twinfield® 2 test from May 2015 to April 2018 were analysed. The global indices (mean deviation, MD, pattern standard deviation, PSD and probability plots) and spherical equivalent were used as parameters of this study. A total of 90 records comprising of 44.4% (40) of males and 55.6% (50) females with the mean age of 29.16 (SD: 10.27) years old and the spherical equivalent was -2.92 (SD:2.94) of the emmetrope, moderate and high myopia. The mean MD index was -1.71 dB (SD 3.95 dB) and PSD was 1.81 dB (SD:1.82 dB) respectively. There is a significant difference between emmetrope, moderate and high myope of MD (X2(2)=8.892, p=0.012) and PSD (X2(2) =42.057, p<0.01). The probability plot shows a significant difference for all quadrant (p<0.01) in P>2%. However, there was only a significant difference noted in temporal (X2(2)=9.47, p<0.01), nasal (X2(2)=11.33, p<0.01) and inferior (X2(2)=11.89, p<0.01) for P<1% probability plots. Pearson correlation test revealed a weak correlation for MD (rs= 0.253) and better correlation for PSD (rs= -0.703) in respective to spherical equivalent. Conclusions: There are localised visual field defect found in a higher degree of myopia, and therefore the visual field test is recommended in moderate to high myopic individuals for monitoring the myopia progression
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信