硅基和碳化硅基变换器对G3电力线通信影响的前瞻性分析

W. E. Sayed, H. Loschi, C. L. Lok, P. Lezynski, R. Smoleński
{"title":"硅基和碳化硅基变换器对G3电力线通信影响的前瞻性分析","authors":"W. E. Sayed, H. Loschi, C. L. Lok, P. Lezynski, R. Smoleński","doi":"10.1109/EMCEUROPE48519.2020.9245727","DOIUrl":null,"url":null,"abstract":"The rapid growth of renewable energy applications increases the complexity of the system, followed by the increase of using fast switching converters in the smart grid. Thus, the probability of electromagnetic interference between the system elements may cause a lot of communication problems between smart grid elements. On the other hand, the use of a SiC-based converter gets a great interest due to its fast switching capability and loss reduction. This paper focuses on studying the difference between the influence of dc Si-based transistor and SiC-based transistor on the performance of narrowband G3-PLC. The experimental setup was implemented to emulate a real situation, and tests were performed to show the results at different operating conditions.","PeriodicalId":332251,"journal":{"name":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Prospective Analysis of the effect of Silicon based and Silicon-Carbide based Converter on G3 Power Line Communication\",\"authors\":\"W. E. Sayed, H. Loschi, C. L. Lok, P. Lezynski, R. Smoleński\",\"doi\":\"10.1109/EMCEUROPE48519.2020.9245727\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The rapid growth of renewable energy applications increases the complexity of the system, followed by the increase of using fast switching converters in the smart grid. Thus, the probability of electromagnetic interference between the system elements may cause a lot of communication problems between smart grid elements. On the other hand, the use of a SiC-based converter gets a great interest due to its fast switching capability and loss reduction. This paper focuses on studying the difference between the influence of dc Si-based transistor and SiC-based transistor on the performance of narrowband G3-PLC. The experimental setup was implemented to emulate a real situation, and tests were performed to show the results at different operating conditions.\",\"PeriodicalId\":332251,\"journal\":{\"name\":\"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCEUROPE48519.2020.9245727\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE48519.2020.9245727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

可再生能源应用的快速增长增加了系统的复杂性,随之而来的是在智能电网中使用快速开关变流器的增加。因此,系统要素之间电磁干扰的概率可能会导致智能电网要素之间出现很多通信问题。另一方面,基于sic的变换器由于其快速开关能力和降低损耗而受到极大的关注。本文重点研究了直流硅基晶体管和硅基晶体管对窄带G3-PLC性能影响的差异。建立了模拟真实情况的实验装置,并进行了不同操作条件下的测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Prospective Analysis of the effect of Silicon based and Silicon-Carbide based Converter on G3 Power Line Communication
The rapid growth of renewable energy applications increases the complexity of the system, followed by the increase of using fast switching converters in the smart grid. Thus, the probability of electromagnetic interference between the system elements may cause a lot of communication problems between smart grid elements. On the other hand, the use of a SiC-based converter gets a great interest due to its fast switching capability and loss reduction. This paper focuses on studying the difference between the influence of dc Si-based transistor and SiC-based transistor on the performance of narrowband G3-PLC. The experimental setup was implemented to emulate a real situation, and tests were performed to show the results at different operating conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信