{"title":"基于一端电压测量和光滑支持向量机的两端输电线路故障精确定位","authors":"Eyada A Alanzi, M. Younis","doi":"10.1109/IEEEGCC.2011.5752591","DOIUrl":null,"url":null,"abstract":"This paper presents a new technique for accurate fault location based on voltage measurement from one end of the two-terminal transmission line and Smooth Support Vector Machine (SSVM). Due to common problems of current transformer during fault location and as a result increasing the cost and reduction of the accuracy, proposed technique is independent of current measurement and based on one terminal voltage measurement of the transmission line. Post-fault voltage at one end of the line is measured and used in calculation of the fault location. GPS (global positioning system) is not required for this technique resulting in a reduction of economic cost. Using the proposed technique, fault location can be estimated with a lower than 0.025% error without using current transformers and GPS. EMTP/ATP simulation and SSVM results show that the proposed fault location technique is independent of fault type, fault resistance and fault inception of the transmission line.","PeriodicalId":119104,"journal":{"name":"2011 IEEE GCC Conference and Exhibition (GCC)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accurate fault location of two-terminal transmission line based on one end voltage measurement and Smooth Support Vector Machines\",\"authors\":\"Eyada A Alanzi, M. Younis\",\"doi\":\"10.1109/IEEEGCC.2011.5752591\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new technique for accurate fault location based on voltage measurement from one end of the two-terminal transmission line and Smooth Support Vector Machine (SSVM). Due to common problems of current transformer during fault location and as a result increasing the cost and reduction of the accuracy, proposed technique is independent of current measurement and based on one terminal voltage measurement of the transmission line. Post-fault voltage at one end of the line is measured and used in calculation of the fault location. GPS (global positioning system) is not required for this technique resulting in a reduction of economic cost. Using the proposed technique, fault location can be estimated with a lower than 0.025% error without using current transformers and GPS. EMTP/ATP simulation and SSVM results show that the proposed fault location technique is independent of fault type, fault resistance and fault inception of the transmission line.\",\"PeriodicalId\":119104,\"journal\":{\"name\":\"2011 IEEE GCC Conference and Exhibition (GCC)\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE GCC Conference and Exhibition (GCC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEEEGCC.2011.5752591\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE GCC Conference and Exhibition (GCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEEEGCC.2011.5752591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Accurate fault location of two-terminal transmission line based on one end voltage measurement and Smooth Support Vector Machines
This paper presents a new technique for accurate fault location based on voltage measurement from one end of the two-terminal transmission line and Smooth Support Vector Machine (SSVM). Due to common problems of current transformer during fault location and as a result increasing the cost and reduction of the accuracy, proposed technique is independent of current measurement and based on one terminal voltage measurement of the transmission line. Post-fault voltage at one end of the line is measured and used in calculation of the fault location. GPS (global positioning system) is not required for this technique resulting in a reduction of economic cost. Using the proposed technique, fault location can be estimated with a lower than 0.025% error without using current transformers and GPS. EMTP/ATP simulation and SSVM results show that the proposed fault location technique is independent of fault type, fault resistance and fault inception of the transmission line.