一种应用于步行机器人足部的电容式压力传感器电路设计

Konstantin Krestovnikov, A. Saveliev, E. Cherskikh
{"title":"一种应用于步行机器人足部的电容式压力传感器电路设计","authors":"Konstantin Krestovnikov, A. Saveliev, E. Cherskikh","doi":"10.1109/MELECON48756.2020.9140509","DOIUrl":null,"url":null,"abstract":"The paper presents development of a circuit solution and a primary detector of a capacitive pressure sensor. Various structural variants of pressure sensors are considered, their characteristics are discussed. Operational principle and structure of the developed primary pressure detector are described, its schematic circuit diagram is presented. The dependency of output signal from the press force is empirically obtained, exhibiting a linear pattern. The estimated value of cyclic drift of the prototype device makes up 0.48% for the upper loading values and 1.08% for the lower ones, by respective weights of 10.69 and 29.03 N. The output signal of the experimental sample is close to linear in the load range from 0 to 8 N, and linear in the range from 8 to 50 N. The sensitivity of the prototype device to the applied pressure is 0.072 V/N. The developed sensor is applied in the feet of a walking robot to determine the zero moment point and calculation of pressure application point on foot.","PeriodicalId":268311,"journal":{"name":"2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of a circuit design for a capacitive pressure sensor, applied in walking robot foot\",\"authors\":\"Konstantin Krestovnikov, A. Saveliev, E. Cherskikh\",\"doi\":\"10.1109/MELECON48756.2020.9140509\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents development of a circuit solution and a primary detector of a capacitive pressure sensor. Various structural variants of pressure sensors are considered, their characteristics are discussed. Operational principle and structure of the developed primary pressure detector are described, its schematic circuit diagram is presented. The dependency of output signal from the press force is empirically obtained, exhibiting a linear pattern. The estimated value of cyclic drift of the prototype device makes up 0.48% for the upper loading values and 1.08% for the lower ones, by respective weights of 10.69 and 29.03 N. The output signal of the experimental sample is close to linear in the load range from 0 to 8 N, and linear in the range from 8 to 50 N. The sensitivity of the prototype device to the applied pressure is 0.072 V/N. The developed sensor is applied in the feet of a walking robot to determine the zero moment point and calculation of pressure application point on foot.\",\"PeriodicalId\":268311,\"journal\":{\"name\":\"2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MELECON48756.2020.9140509\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 20th Mediterranean Electrotechnical Conference ( MELECON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MELECON48756.2020.9140509","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了一种电容式压力传感器的电路解决方案和主检测器的研制。考虑了压力传感器的各种结构形式,讨论了它们的特点。介绍了研制的一次压力检测器的工作原理和结构,并给出了原理电路。根据经验得到了输出信号与压力力的相关性,显示出线性模式。上加载值和下加载值的循环漂移估定值分别占0.48%和1.08%,权重分别为10.69和29.03 N。实验样品的输出信号在0 ~ 8 N的负载范围内接近线性,在8 ~ 50 N的负载范围内接近线性,对施加压力的灵敏度为0.072 V/N。将所研制的传感器应用于步行机器人的足部,确定足部零力矩点并计算足部施加压力点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a circuit design for a capacitive pressure sensor, applied in walking robot foot
The paper presents development of a circuit solution and a primary detector of a capacitive pressure sensor. Various structural variants of pressure sensors are considered, their characteristics are discussed. Operational principle and structure of the developed primary pressure detector are described, its schematic circuit diagram is presented. The dependency of output signal from the press force is empirically obtained, exhibiting a linear pattern. The estimated value of cyclic drift of the prototype device makes up 0.48% for the upper loading values and 1.08% for the lower ones, by respective weights of 10.69 and 29.03 N. The output signal of the experimental sample is close to linear in the load range from 0 to 8 N, and linear in the range from 8 to 50 N. The sensitivity of the prototype device to the applied pressure is 0.072 V/N. The developed sensor is applied in the feet of a walking robot to determine the zero moment point and calculation of pressure application point on foot.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信