{"title":"Rancang Bangun Sistem Monitoring dan Uji Analisis Performansi Tranformator berbasis Internet of Things (IoT)","authors":"S. Aditya, Samuel Jie, Achmad Nur Aliansyah","doi":"10.33772/jfe.v7i2.25345","DOIUrl":null,"url":null,"abstract":"Maintenance on transformers is currently carried out on a monthly basis, which activities are carried out manually so that it is difficult to detect transformers experiencing abnormal conditions if there is a disturbance outside the maintenance schedule. Therefore, this research was carried out with the aim of making a prototype of a transformer condition monitoring system and monitoring parameters on the transformer remotely through the Blynk application in real time. In making this tool, the PZEM-004T sensor is used to read electrical parameters, the DS18B20 sensor to read the temperature on the transformer winding and the Arduino MEGA 2560 With WiFi Built-in - ESP8266 to process the data read by the sensor which is then sent to the Blynk application. The results of this study indicate that the average error value for the comparison of current readings is 0.68%, the average error value for the comparison between phase to neutral voltage readings is 0.91%, the average error value for the comparison of voltage readings between phases is 1, 00%, the average error value of the Cosφ reading comparison is 0.02% and the average temperature reading comparison error value is 1.73%.","PeriodicalId":164637,"journal":{"name":"Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Fokus Elektroda : Energi Listrik, Telekomunikasi, Komputer, Elektronika dan Kendali)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33772/jfe.v7i2.25345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目前对变压器的维护是按月进行的,这些活动都是人工进行的,因此如果在维护计划之外存在干扰,则很难检测到变压器出现异常情况。因此,本研究的目的是制作一台变压器状态监测系统样机,并通过Blynk应用程序对变压器的参数进行远程实时监测。在制作此工具时,pzm - 004t传感器用于读取电气参数,DS18B20传感器用于读取变压器绕组上的温度,Arduino MEGA 2560 With WiFi内置- ESP8266用于处理传感器读取的数据,然后将其发送到Blynk应用程序。研究结果表明,电流读数比较的平均误差值为0.68%,相与中性电压读数比较的平均误差值为0.91%,相间电压读数比较的平均误差值为1.00%,Cosφ读数比较的平均误差值为0.02%,温度读数比较的平均误差值为1.73%。
Rancang Bangun Sistem Monitoring dan Uji Analisis Performansi Tranformator berbasis Internet of Things (IoT)
Maintenance on transformers is currently carried out on a monthly basis, which activities are carried out manually so that it is difficult to detect transformers experiencing abnormal conditions if there is a disturbance outside the maintenance schedule. Therefore, this research was carried out with the aim of making a prototype of a transformer condition monitoring system and monitoring parameters on the transformer remotely through the Blynk application in real time. In making this tool, the PZEM-004T sensor is used to read electrical parameters, the DS18B20 sensor to read the temperature on the transformer winding and the Arduino MEGA 2560 With WiFi Built-in - ESP8266 to process the data read by the sensor which is then sent to the Blynk application. The results of this study indicate that the average error value for the comparison of current readings is 0.68%, the average error value for the comparison between phase to neutral voltage readings is 0.91%, the average error value for the comparison of voltage readings between phases is 1, 00%, the average error value of the Cosφ reading comparison is 0.02% and the average temperature reading comparison error value is 1.73%.