智能电网的综合监控

A. Alouani
{"title":"智能电网的综合监控","authors":"A. Alouani","doi":"10.1109/FIIW.2012.6378318","DOIUrl":null,"url":null,"abstract":"In the current practice of power system monitoring and control, different devices are separately designed to perform different functions. Power systems measurement devices collect data and communicate it to a data concentrator for processing. Intelligent electronic devices (IED) are designed independently to perform different protection functions. Different providers of the IED use different communication protocols. The bulkiness, cost, and communication requirements of implementing the monitoring, control and protection functions independently can be avoided by designing a new generation of smart power devices that implement these functions inside a standalone single device. This paper discusses the design, development, and testing of a low cost integrated intelligent Phasor measurement unit (IIPMU) that integrates the functions of data acquisition, state estimation, and protection and control in the same stand alone device.","PeriodicalId":170653,"journal":{"name":"2012 Future of Instrumentation International Workshop (FIIW) Proceedings","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Integrated monitoring and control in smart grid\",\"authors\":\"A. Alouani\",\"doi\":\"10.1109/FIIW.2012.6378318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the current practice of power system monitoring and control, different devices are separately designed to perform different functions. Power systems measurement devices collect data and communicate it to a data concentrator for processing. Intelligent electronic devices (IED) are designed independently to perform different protection functions. Different providers of the IED use different communication protocols. The bulkiness, cost, and communication requirements of implementing the monitoring, control and protection functions independently can be avoided by designing a new generation of smart power devices that implement these functions inside a standalone single device. This paper discusses the design, development, and testing of a low cost integrated intelligent Phasor measurement unit (IIPMU) that integrates the functions of data acquisition, state estimation, and protection and control in the same stand alone device.\",\"PeriodicalId\":170653,\"journal\":{\"name\":\"2012 Future of Instrumentation International Workshop (FIIW) Proceedings\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Future of Instrumentation International Workshop (FIIW) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FIIW.2012.6378318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Future of Instrumentation International Workshop (FIIW) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FIIW.2012.6378318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在目前的电力系统监控实践中,不同的设备被单独设计来完成不同的功能。电力系统测量设备收集数据并将其传送到数据集中器进行处理。智能电子设备(IED)是独立设计的,可以执行不同的保护功能。IED的不同提供者使用不同的通信协议。通过设计在独立的单个设备中实现这些功能的新一代智能电源设备,可以避免独立实现监视、控制和保护功能的体积、成本和通信需求。本文讨论了一种低成本集成智能相量测量单元(IIPMU)的设计、开发和测试,该单元在同一台独立设备中集成了数据采集、状态估计和保护控制功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Integrated monitoring and control in smart grid
In the current practice of power system monitoring and control, different devices are separately designed to perform different functions. Power systems measurement devices collect data and communicate it to a data concentrator for processing. Intelligent electronic devices (IED) are designed independently to perform different protection functions. Different providers of the IED use different communication protocols. The bulkiness, cost, and communication requirements of implementing the monitoring, control and protection functions independently can be avoided by designing a new generation of smart power devices that implement these functions inside a standalone single device. This paper discusses the design, development, and testing of a low cost integrated intelligent Phasor measurement unit (IIPMU) that integrates the functions of data acquisition, state estimation, and protection and control in the same stand alone device.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信