Huseyin Acar, M. Akin, Abdulnasir Yildiz, Hakki Egi, G. Kirbas
{"title":"利用TMS320C6713 DSK和MATLAB对脑电信号进行警觉性等级分类","authors":"Huseyin Acar, M. Akin, Abdulnasir Yildiz, Hakki Egi, G. Kirbas","doi":"10.1109/SIU.2010.5650884","DOIUrl":null,"url":null,"abstract":"In this study, electroencephalogram (EEG) signals recorded during transition from wakefulness to sleep and Matlab-Simulink and TMS320C6713 DSP Starter Kit (DSK) of Texas Instruments Inc. are used for classification of alertness level. First, EEG signals taken from 8 healthy subjects were separated as alert, drowsy, and sleep signals in the form of 5 s epochs with the aid of expert doctor. The subbands(feature vector) of each EEG signals were obtained by using Discrete Wavelet Transform. Some statistical operations were used to reduce dimensions of feature vectors and obtained vectors were chosen as input feature vectors of multilayer neural network which is used as classifier. The Simulink model for real time classification process was run on DSK. The tests showed that the results of classification with DSK are same with the results of classification simulation without using DSK. Total classification accuracy obtained in the test results of proposed model showed that the model can be used in the estimation of alertness level.","PeriodicalId":152297,"journal":{"name":"2010 IEEE 18th Signal Processing and Communications Applications Conference","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The classification of alertness level from EEG signals by using TMS320C6713 DSK and MATLAB\",\"authors\":\"Huseyin Acar, M. Akin, Abdulnasir Yildiz, Hakki Egi, G. Kirbas\",\"doi\":\"10.1109/SIU.2010.5650884\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, electroencephalogram (EEG) signals recorded during transition from wakefulness to sleep and Matlab-Simulink and TMS320C6713 DSP Starter Kit (DSK) of Texas Instruments Inc. are used for classification of alertness level. First, EEG signals taken from 8 healthy subjects were separated as alert, drowsy, and sleep signals in the form of 5 s epochs with the aid of expert doctor. The subbands(feature vector) of each EEG signals were obtained by using Discrete Wavelet Transform. Some statistical operations were used to reduce dimensions of feature vectors and obtained vectors were chosen as input feature vectors of multilayer neural network which is used as classifier. The Simulink model for real time classification process was run on DSK. The tests showed that the results of classification with DSK are same with the results of classification simulation without using DSK. Total classification accuracy obtained in the test results of proposed model showed that the model can be used in the estimation of alertness level.\",\"PeriodicalId\":152297,\"journal\":{\"name\":\"2010 IEEE 18th Signal Processing and Communications Applications Conference\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE 18th Signal Processing and Communications Applications Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIU.2010.5650884\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE 18th Signal Processing and Communications Applications Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIU.2010.5650884","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The classification of alertness level from EEG signals by using TMS320C6713 DSK and MATLAB
In this study, electroencephalogram (EEG) signals recorded during transition from wakefulness to sleep and Matlab-Simulink and TMS320C6713 DSP Starter Kit (DSK) of Texas Instruments Inc. are used for classification of alertness level. First, EEG signals taken from 8 healthy subjects were separated as alert, drowsy, and sleep signals in the form of 5 s epochs with the aid of expert doctor. The subbands(feature vector) of each EEG signals were obtained by using Discrete Wavelet Transform. Some statistical operations were used to reduce dimensions of feature vectors and obtained vectors were chosen as input feature vectors of multilayer neural network which is used as classifier. The Simulink model for real time classification process was run on DSK. The tests showed that the results of classification with DSK are same with the results of classification simulation without using DSK. Total classification accuracy obtained in the test results of proposed model showed that the model can be used in the estimation of alertness level.