{"title":"表征半导体器件机械应力敏感性的压测针技术","authors":"H. Tuinhout, Oliver Dieball","doi":"10.1109/ICMTS55420.2023.10094063","DOIUrl":null,"url":null,"abstract":"This paper discusses the so called Pressing Probe Needle (PPN) technique for characterizing out-of-plane mechanical stress sensitivity of arbitrary semiconductor devices, implemented on a standard parametric test system. By utilizing a motorized probe positioner and a force calibrated standard tungsten parametric probe needle, this fast and highspatial-resolution technique provides valuable insights into mechanical stress effects of process and device layout options. Such results are highly beneficial for high-precision analog circuit design and layout optimization.","PeriodicalId":275144,"journal":{"name":"2023 35th International Conference on Microelectronic Test Structure (ICMTS)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Pressing Probe Needle Technique for Characterizing Mechanical Stress Sensitivity of Semiconductor Devices\",\"authors\":\"H. Tuinhout, Oliver Dieball\",\"doi\":\"10.1109/ICMTS55420.2023.10094063\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the so called Pressing Probe Needle (PPN) technique for characterizing out-of-plane mechanical stress sensitivity of arbitrary semiconductor devices, implemented on a standard parametric test system. By utilizing a motorized probe positioner and a force calibrated standard tungsten parametric probe needle, this fast and highspatial-resolution technique provides valuable insights into mechanical stress effects of process and device layout options. Such results are highly beneficial for high-precision analog circuit design and layout optimization.\",\"PeriodicalId\":275144,\"journal\":{\"name\":\"2023 35th International Conference on Microelectronic Test Structure (ICMTS)\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 35th International Conference on Microelectronic Test Structure (ICMTS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMTS55420.2023.10094063\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 35th International Conference on Microelectronic Test Structure (ICMTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMTS55420.2023.10094063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Pressing Probe Needle Technique for Characterizing Mechanical Stress Sensitivity of Semiconductor Devices
This paper discusses the so called Pressing Probe Needle (PPN) technique for characterizing out-of-plane mechanical stress sensitivity of arbitrary semiconductor devices, implemented on a standard parametric test system. By utilizing a motorized probe positioner and a force calibrated standard tungsten parametric probe needle, this fast and highspatial-resolution technique provides valuable insights into mechanical stress effects of process and device layout options. Such results are highly beneficial for high-precision analog circuit design and layout optimization.