{"title":"开关磁阻电机直接转矩控制中的调速器设计","authors":"A. Krasovsky, S. Vasyukov, Sergey Kuznetsov","doi":"10.1109/ICIEAM.2019.8743036","DOIUrl":null,"url":null,"abstract":"A method has been developed for determining the parameters of the speed regulator of a switched reluctance motor in a two-circuit structure of a subordinate control with an internal circuit of direct torque control. The connection of the limit values of the rate of change of the moment with the drive parameters limiting the zone of linear operation of the control system has been determined. Theoretical conclusions are confirmed by the results of simulation.","PeriodicalId":221976,"journal":{"name":"2019 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of Speed Regulator at Direct Torque Control of Switched Reluctance Motors\",\"authors\":\"A. Krasovsky, S. Vasyukov, Sergey Kuznetsov\",\"doi\":\"10.1109/ICIEAM.2019.8743036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method has been developed for determining the parameters of the speed regulator of a switched reluctance motor in a two-circuit structure of a subordinate control with an internal circuit of direct torque control. The connection of the limit values of the rate of change of the moment with the drive parameters limiting the zone of linear operation of the control system has been determined. Theoretical conclusions are confirmed by the results of simulation.\",\"PeriodicalId\":221976,\"journal\":{\"name\":\"2019 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEAM.2019.8743036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEAM.2019.8743036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of Speed Regulator at Direct Torque Control of Switched Reluctance Motors
A method has been developed for determining the parameters of the speed regulator of a switched reluctance motor in a two-circuit structure of a subordinate control with an internal circuit of direct torque control. The connection of the limit values of the rate of change of the moment with the drive parameters limiting the zone of linear operation of the control system has been determined. Theoretical conclusions are confirmed by the results of simulation.