{"title":"六步运行模式下永磁同步发电机并联运行","authors":"Jonghun Yun, Young-Kwang Son, S. Sul","doi":"10.1109/ITEC53557.2022.9814065","DOIUrl":null,"url":null,"abstract":"In the shipboard dc power system, dc bus voltage regulation through six-step operation of active front end (AFE) can conspicuously reduce converter loss, compared to PWM operation of AFE. Despite of the superior efficiency of the six-step operation, there have been few researches on the parallel operation of generators under the six-step operation. This paper proposes a framework for the parallel operation of permanent magnet generators (PMGs) under the six-step operation. In addition, a method for deriving the optimal dc bus voltage to minimize the total copper loss of paralleled PMGs with different parameters is proposed. The proposed optimal voltage regulation method is compared with methods only minimizing copper loss of a single PMG among the paralleled PMGs. By the optimal voltage regulation, the total copper loss can be reduced by up to 9.1 % and 29 %, in the simulation and the experiment, respectively.","PeriodicalId":275570,"journal":{"name":"2022 IEEE Transportation Electrification Conference & Expo (ITEC)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Parallel Operation of Permanent Magnet Synchronous Generators under Six-Step Operation Mode\",\"authors\":\"Jonghun Yun, Young-Kwang Son, S. Sul\",\"doi\":\"10.1109/ITEC53557.2022.9814065\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the shipboard dc power system, dc bus voltage regulation through six-step operation of active front end (AFE) can conspicuously reduce converter loss, compared to PWM operation of AFE. Despite of the superior efficiency of the six-step operation, there have been few researches on the parallel operation of generators under the six-step operation. This paper proposes a framework for the parallel operation of permanent magnet generators (PMGs) under the six-step operation. In addition, a method for deriving the optimal dc bus voltage to minimize the total copper loss of paralleled PMGs with different parameters is proposed. The proposed optimal voltage regulation method is compared with methods only minimizing copper loss of a single PMG among the paralleled PMGs. By the optimal voltage regulation, the total copper loss can be reduced by up to 9.1 % and 29 %, in the simulation and the experiment, respectively.\",\"PeriodicalId\":275570,\"journal\":{\"name\":\"2022 IEEE Transportation Electrification Conference & Expo (ITEC)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Transportation Electrification Conference & Expo (ITEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITEC53557.2022.9814065\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Transportation Electrification Conference & Expo (ITEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITEC53557.2022.9814065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在船舶直流电源系统中,通过主动前端(AFE)的六步操作来调节直流母线电压,与主动前端的PWM操作相比,可以显著降低变换器的损耗。尽管六步运行具有优越的效率,但对六步运行下发电机并联运行的研究很少。提出了永磁发电机并联运行的六步运行框架。此外,还提出了一种计算并联永磁调速器不同参数时的最佳直流母线电压的方法。将所提出的最优电压调节方法与并联PMG中仅使单个PMG铜损耗最小的方法进行了比较。通过优化的电压调节,在仿真和实验中,铜的总损耗分别降低了9.1%和29%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Parallel Operation of Permanent Magnet Synchronous Generators under Six-Step Operation Mode
In the shipboard dc power system, dc bus voltage regulation through six-step operation of active front end (AFE) can conspicuously reduce converter loss, compared to PWM operation of AFE. Despite of the superior efficiency of the six-step operation, there have been few researches on the parallel operation of generators under the six-step operation. This paper proposes a framework for the parallel operation of permanent magnet generators (PMGs) under the six-step operation. In addition, a method for deriving the optimal dc bus voltage to minimize the total copper loss of paralleled PMGs with different parameters is proposed. The proposed optimal voltage regulation method is compared with methods only minimizing copper loss of a single PMG among the paralleled PMGs. By the optimal voltage regulation, the total copper loss can be reduced by up to 9.1 % and 29 %, in the simulation and the experiment, respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信