电感测量使用LCR表和电流互感器接口

B. Waltrip, S. Avramov-Zamurovic, A. Koffman
{"title":"电感测量使用LCR表和电流互感器接口","authors":"B. Waltrip, S. Avramov-Zamurovic, A. Koffman","doi":"10.1109/IMTC.2005.1604290","DOIUrl":null,"url":null,"abstract":"This paper describes a new inductance measurement system based on a commercially available LCR meter, a commercially available audio frequency capacitance bridge, 4 terminal-pair (4TP) capacitance and resistance standards, and a multi-stage, programmable-ratio, current transformer. The described measurement system synthesizes equivalent inductance values using the current transformer to combine the applied currents through programmable resistance and capacitance standards. The system takes advantage of the inherent measurement linearity of the LCR meter, and achieves acceptable inductance measurement uncertainty over the 50 Hz to 20 kHz frequency range","PeriodicalId":244878,"journal":{"name":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Inductance Measurement Using an LCR Meter and a Current Transformer Interface\",\"authors\":\"B. Waltrip, S. Avramov-Zamurovic, A. Koffman\",\"doi\":\"10.1109/IMTC.2005.1604290\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes a new inductance measurement system based on a commercially available LCR meter, a commercially available audio frequency capacitance bridge, 4 terminal-pair (4TP) capacitance and resistance standards, and a multi-stage, programmable-ratio, current transformer. The described measurement system synthesizes equivalent inductance values using the current transformer to combine the applied currents through programmable resistance and capacitance standards. The system takes advantage of the inherent measurement linearity of the LCR meter, and achieves acceptable inductance measurement uncertainty over the 50 Hz to 20 kHz frequency range\",\"PeriodicalId\":244878,\"journal\":{\"name\":\"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings\",\"volume\":\"114 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.2005.1604290\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2005.1604290","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文介绍了一种新的电感测量系统,该系统基于市售LCR表、市售音频电容桥、4个终端对(4TP)电容和电阻标准以及多级可编程比电流互感器。所描述的测量系统利用电流互感器通过可编程电阻和电容标准来组合施加的电流,从而合成等效电感值。该系统利用LCR表固有的测量线性度,在50 Hz ~ 20 kHz频率范围内实现了可接受的电感测量不确定度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inductance Measurement Using an LCR Meter and a Current Transformer Interface
This paper describes a new inductance measurement system based on a commercially available LCR meter, a commercially available audio frequency capacitance bridge, 4 terminal-pair (4TP) capacitance and resistance standards, and a multi-stage, programmable-ratio, current transformer. The described measurement system synthesizes equivalent inductance values using the current transformer to combine the applied currents through programmable resistance and capacitance standards. The system takes advantage of the inherent measurement linearity of the LCR meter, and achieves acceptable inductance measurement uncertainty over the 50 Hz to 20 kHz frequency range
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信