A. Zarubin, A. Tyazhev, I.P. Nam, S. Ryabkov, M. Rozhnev
{"title":"基于多通道GaAs探测器的660kev γ -量子计数器","authors":"A. Zarubin, A. Tyazhev, I.P. Nam, S. Ryabkov, M. Rozhnev","doi":"10.1109/SIBCON.2007.371335","DOIUrl":null,"url":null,"abstract":"Results obtained from development, testing, and evaluation of 660 keV gamma-quantum counter based on multichannel GaAs detector are presented. The counter operated in quantum count mode and counting rate up to 1000 quanta/(s-cm3) have been demonstrated for 30 cm distance between detector and 660 keV gamma-quanta source.","PeriodicalId":131657,"journal":{"name":"2007 Siberian Conference on Control and Communications","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"660 keV Gamma-Quanta Counter Based on Multichannel GaAs Detector\",\"authors\":\"A. Zarubin, A. Tyazhev, I.P. Nam, S. Ryabkov, M. Rozhnev\",\"doi\":\"10.1109/SIBCON.2007.371335\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Results obtained from development, testing, and evaluation of 660 keV gamma-quantum counter based on multichannel GaAs detector are presented. The counter operated in quantum count mode and counting rate up to 1000 quanta/(s-cm3) have been demonstrated for 30 cm distance between detector and 660 keV gamma-quanta source.\",\"PeriodicalId\":131657,\"journal\":{\"name\":\"2007 Siberian Conference on Control and Communications\",\"volume\":\"96 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Siberian Conference on Control and Communications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIBCON.2007.371335\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Siberian Conference on Control and Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIBCON.2007.371335","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
660 keV Gamma-Quanta Counter Based on Multichannel GaAs Detector
Results obtained from development, testing, and evaluation of 660 keV gamma-quantum counter based on multichannel GaAs detector are presented. The counter operated in quantum count mode and counting rate up to 1000 quanta/(s-cm3) have been demonstrated for 30 cm distance between detector and 660 keV gamma-quanta source.