{"title":"测试供电tsv","authors":"Hua-Xuan Li, H. Fu, Shi-Yu Huang, Jin-Cheng Jiang, D. Kwai, Yung-Fa Chou","doi":"10.1109/ACQED.2015.7274021","DOIUrl":null,"url":null,"abstract":"Many TSVs in a 3D IC are not used for signal transmission but for power delivery. Techniques needed to detect them have not been studied in-depth in the literature. In this paper, we present a test method for power-delivery TSVs, by embedding ring-oscillator (RO) based monitors (in a scalable architecture) to detect if there is any excessive voltage-drop at the end of any TSV during a manufacturing test session. One key feature as opposed to previous RO-based methods is that our approach is able to detect the worst-case dynamic voltage-drop (occurring in a very short period of time such as 1ns), rather than just the average voltage-drop over a long period of time. This is essential in order to detect small defects inside the power delivery network. These defects, if not detected, could set off a transient timing failure when the IC is operated in a system.","PeriodicalId":376857,"journal":{"name":"2015 6th Asia Symposium on Quality Electronic Design (ASQED)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Testing power-delivery TSVs\",\"authors\":\"Hua-Xuan Li, H. Fu, Shi-Yu Huang, Jin-Cheng Jiang, D. Kwai, Yung-Fa Chou\",\"doi\":\"10.1109/ACQED.2015.7274021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many TSVs in a 3D IC are not used for signal transmission but for power delivery. Techniques needed to detect them have not been studied in-depth in the literature. In this paper, we present a test method for power-delivery TSVs, by embedding ring-oscillator (RO) based monitors (in a scalable architecture) to detect if there is any excessive voltage-drop at the end of any TSV during a manufacturing test session. One key feature as opposed to previous RO-based methods is that our approach is able to detect the worst-case dynamic voltage-drop (occurring in a very short period of time such as 1ns), rather than just the average voltage-drop over a long period of time. This is essential in order to detect small defects inside the power delivery network. These defects, if not detected, could set off a transient timing failure when the IC is operated in a system.\",\"PeriodicalId\":376857,\"journal\":{\"name\":\"2015 6th Asia Symposium on Quality Electronic Design (ASQED)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 6th Asia Symposium on Quality Electronic Design (ASQED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ACQED.2015.7274021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 6th Asia Symposium on Quality Electronic Design (ASQED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACQED.2015.7274021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

3D集成电路中的许多tsv不是用于信号传输,而是用于功率传输。检测它们所需的技术尚未在文献中进行深入研究。在本文中,我们提出了一种测试功率输出TSV的方法,通过嵌入基于环形振荡器(RO)的监视器(在可扩展的架构中)来检测在制造测试过程中任何TSV的末端是否存在任何过大的压降。与以前基于ro的方法相比,一个关键特征是我们的方法能够检测最坏情况下的动态压降(发生在非常短的时间内,例如1ns),而不仅仅是长时间内的平均压降。这对于检测输电网内部的小缺陷至关重要。当集成电路在系统中运行时,如果不检测到这些缺陷,可能会引发瞬态定时故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Testing power-delivery TSVs
Many TSVs in a 3D IC are not used for signal transmission but for power delivery. Techniques needed to detect them have not been studied in-depth in the literature. In this paper, we present a test method for power-delivery TSVs, by embedding ring-oscillator (RO) based monitors (in a scalable architecture) to detect if there is any excessive voltage-drop at the end of any TSV during a manufacturing test session. One key feature as opposed to previous RO-based methods is that our approach is able to detect the worst-case dynamic voltage-drop (occurring in a very short period of time such as 1ns), rather than just the average voltage-drop over a long period of time. This is essential in order to detect small defects inside the power delivery network. These defects, if not detected, could set off a transient timing failure when the IC is operated in a system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信