746试验母线系统的欠压减载研究

R. Verayiah, A. Ramasamy, H. Abidin, I. Musirin
{"title":"746试验母线系统的欠压减载研究","authors":"R. Verayiah, A. Ramasamy, H. Abidin, I. Musirin","doi":"10.1109/ICEENVIRON.2009.5398661","DOIUrl":null,"url":null,"abstract":"Voltage collapse phenomenon is known to be complex and localized in nature but with a widespread effect. The ultimate effect of voltage collapse would be total system collapse which would incur high losses to utility companies. Thus, on- line monitoring of power system stability has become a vital factor for electric utility companies. One of the methods to avoid voltage collapse is to perform Under Voltage Load Shedding (UVLS). Fast Voltage Stability Index (FVSI) index is proven to be a good indicator for voltage stability in a system. This paper analyzes the correlation between FVSI and the placement of UVLS relays for a 746 test bus system. It is found from the simulations results that FVSI index can be used as an indicator for the placement of UVLS relays in a power system network.","PeriodicalId":211736,"journal":{"name":"2009 3rd International Conference on Energy and Environment (ICEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Under Voltage Load Shedding (UVLS) study for 746 test bus system\",\"authors\":\"R. Verayiah, A. Ramasamy, H. Abidin, I. Musirin\",\"doi\":\"10.1109/ICEENVIRON.2009.5398661\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltage collapse phenomenon is known to be complex and localized in nature but with a widespread effect. The ultimate effect of voltage collapse would be total system collapse which would incur high losses to utility companies. Thus, on- line monitoring of power system stability has become a vital factor for electric utility companies. One of the methods to avoid voltage collapse is to perform Under Voltage Load Shedding (UVLS). Fast Voltage Stability Index (FVSI) index is proven to be a good indicator for voltage stability in a system. This paper analyzes the correlation between FVSI and the placement of UVLS relays for a 746 test bus system. It is found from the simulations results that FVSI index can be used as an indicator for the placement of UVLS relays in a power system network.\",\"PeriodicalId\":211736,\"journal\":{\"name\":\"2009 3rd International Conference on Energy and Environment (ICEE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 3rd International Conference on Energy and Environment (ICEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEENVIRON.2009.5398661\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 3rd International Conference on Energy and Environment (ICEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEENVIRON.2009.5398661","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

电压崩溃现象是一个复杂的局部现象,但影响广泛。电压崩溃的最终影响将是整个系统的崩溃,这将给公用事业公司带来巨大的损失。因此,对电力系统的稳定性进行在线监测已成为电力公司的一项重要工作。避免电压崩溃的方法之一是进行欠压减载(UVLS)。快速电压稳定指数(FVSI)指标被证明是一个很好的系统电压稳定性指标。本文分析了746测试母线系统的FVSI与UVLS继电器位置的相关性。仿真结果表明,FVSI指标可以作为UVLS继电器在电网中布置的指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Under Voltage Load Shedding (UVLS) study for 746 test bus system
Voltage collapse phenomenon is known to be complex and localized in nature but with a widespread effect. The ultimate effect of voltage collapse would be total system collapse which would incur high losses to utility companies. Thus, on- line monitoring of power system stability has become a vital factor for electric utility companies. One of the methods to avoid voltage collapse is to perform Under Voltage Load Shedding (UVLS). Fast Voltage Stability Index (FVSI) index is proven to be a good indicator for voltage stability in a system. This paper analyzes the correlation between FVSI and the placement of UVLS relays for a 746 test bus system. It is found from the simulations results that FVSI index can be used as an indicator for the placement of UVLS relays in a power system network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信