串联谐振变换器的线性控制

D. Tahri, K. Drissi El Khamlichi, J. Gaubert, A. Jaafari
{"title":"串联谐振变换器的线性控制","authors":"D. Tahri, K. Drissi El Khamlichi, J. Gaubert, A. Jaafari","doi":"10.1109/CIPE.1994.396704","DOIUrl":null,"url":null,"abstract":"A new method called \"linear control\" is suggested to command a series resonant power converter operating above the resonant frequency. Its principle is to control, simultaneously, the levels of energy storage elements L and C in a simple way: a linear combination of the two state variables of the resonant circuit. This process notably favours HF DC-DC conversion, giving also fast dynamics close to those of optimal trajectory control. In addition, this method is very easy to apply analogically as well as numerically and in both cases the cost is minimal. Numerical simulation results confirm the performance of the linear control for the transient regime. This strategy can be easily applied to other types of resonance (parallel or series-parallel) operating at frequencies below and above the resonant frequency.<<ETX>>","PeriodicalId":123138,"journal":{"name":"Proceedings of 1994 IEEE Workshop on Computers in Power Electronics","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Linear control of series resonant converter\",\"authors\":\"D. Tahri, K. Drissi El Khamlichi, J. Gaubert, A. Jaafari\",\"doi\":\"10.1109/CIPE.1994.396704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new method called \\\"linear control\\\" is suggested to command a series resonant power converter operating above the resonant frequency. Its principle is to control, simultaneously, the levels of energy storage elements L and C in a simple way: a linear combination of the two state variables of the resonant circuit. This process notably favours HF DC-DC conversion, giving also fast dynamics close to those of optimal trajectory control. In addition, this method is very easy to apply analogically as well as numerically and in both cases the cost is minimal. Numerical simulation results confirm the performance of the linear control for the transient regime. This strategy can be easily applied to other types of resonance (parallel or series-parallel) operating at frequencies below and above the resonant frequency.<<ETX>>\",\"PeriodicalId\":123138,\"journal\":{\"name\":\"Proceedings of 1994 IEEE Workshop on Computers in Power Electronics\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1994 IEEE Workshop on Computers in Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIPE.1994.396704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 IEEE Workshop on Computers in Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIPE.1994.396704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种新的“线性控制”方法来控制串联谐振功率变换器在谐振频率以上工作。其原理是用一种简单的方法同时控制储能元件L和C的电平:谐振电路的两个状态变量的线性组合。这个过程特别有利于高频DC-DC转换,也提供了接近最优轨迹控制的快速动力学。此外,这种方法很容易应用类比和数值,在这两种情况下,成本是最小的。数值仿真结果证实了线性控制在暂态状态下的有效性。这种策略可以很容易地应用于其他类型的谐振(并联或串并联),工作频率低于或高于谐振频率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Linear control of series resonant converter
A new method called "linear control" is suggested to command a series resonant power converter operating above the resonant frequency. Its principle is to control, simultaneously, the levels of energy storage elements L and C in a simple way: a linear combination of the two state variables of the resonant circuit. This process notably favours HF DC-DC conversion, giving also fast dynamics close to those of optimal trajectory control. In addition, this method is very easy to apply analogically as well as numerically and in both cases the cost is minimal. Numerical simulation results confirm the performance of the linear control for the transient regime. This strategy can be easily applied to other types of resonance (parallel or series-parallel) operating at frequencies below and above the resonant frequency.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信