改进交流市电电能质量的并网太阳能光伏发电系统

Aran Kumar Verma, Bhim Singh, D. Shahani
{"title":"改进交流市电电能质量的并网太阳能光伏发电系统","authors":"Aran Kumar Verma, Bhim Singh, D. Shahani","doi":"10.1109/ICSET.2012.6357394","DOIUrl":null,"url":null,"abstract":"This paper presents a novel concept of utilizing solar photovoltaic (SPV) generating systems to improve the power factor to unity or to regulate a voltage at point of common coupling (PCC) of a three phase system. A three-phase VSC (voltage source converter) of this system eliminates harmonics currents, balances loads and compensates reactive power for power factor correction (PFC) or zero voltage regulation (ZVR) at AC mains. The VSC consists of a DC bus capacitor at its DC bus which is fed by SPV energy. DC voltage PI controller regulates the DC bus voltage at the time of load variation. The grid interfaced solar PV power generating system is tested for PFC and ZVR mode of operation along with harmonics currents elimination and load balancing of linear and nonlinear loads.","PeriodicalId":256740,"journal":{"name":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"75","resultStr":"{\"title\":\"Grid interfaced solar photovoltaic power generating system with power quality improvement at AC mains\",\"authors\":\"Aran Kumar Verma, Bhim Singh, D. Shahani\",\"doi\":\"10.1109/ICSET.2012.6357394\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a novel concept of utilizing solar photovoltaic (SPV) generating systems to improve the power factor to unity or to regulate a voltage at point of common coupling (PCC) of a three phase system. A three-phase VSC (voltage source converter) of this system eliminates harmonics currents, balances loads and compensates reactive power for power factor correction (PFC) or zero voltage regulation (ZVR) at AC mains. The VSC consists of a DC bus capacitor at its DC bus which is fed by SPV energy. DC voltage PI controller regulates the DC bus voltage at the time of load variation. The grid interfaced solar PV power generating system is tested for PFC and ZVR mode of operation along with harmonics currents elimination and load balancing of linear and nonlinear loads.\",\"PeriodicalId\":256740,\"journal\":{\"name\":\"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"75\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSET.2012.6357394\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2012.6357394","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 75

摘要

本文提出了一种利用太阳能光伏发电系统来提高三相系统的功率因数或调节三相系统的共耦合点电压的新概念。该系统的三相VSC(电压源转换器)消除谐波电流,平衡负载并补偿交流电源的功率因数校正(PFC)或零电压调节(ZVR)的无功功率。VSC由直流母线上的直流母线电容器组成,该直流母线由SPV能量馈送。直流电压PI控制器在负载变化时调节直流母线电压。对并网太阳能光伏发电系统进行了PFC和ZVR两种运行方式的测试,并对线性和非线性负载进行了谐波电流消除和负载平衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Grid interfaced solar photovoltaic power generating system with power quality improvement at AC mains
This paper presents a novel concept of utilizing solar photovoltaic (SPV) generating systems to improve the power factor to unity or to regulate a voltage at point of common coupling (PCC) of a three phase system. A three-phase VSC (voltage source converter) of this system eliminates harmonics currents, balances loads and compensates reactive power for power factor correction (PFC) or zero voltage regulation (ZVR) at AC mains. The VSC consists of a DC bus capacitor at its DC bus which is fed by SPV energy. DC voltage PI controller regulates the DC bus voltage at the time of load variation. The grid interfaced solar PV power generating system is tested for PFC and ZVR mode of operation along with harmonics currents elimination and load balancing of linear and nonlinear loads.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信