一种基于Q-f下垂与RPV相结合的新型防孤岛防护方法

O. Raipala, A. Makinen, S. Repo, P. Jarventausta
{"title":"一种基于Q-f下垂与RPV相结合的新型防孤岛防护方法","authors":"O. Raipala, A. Makinen, S. Repo, P. Jarventausta","doi":"10.1109/ISGTEUROPE.2014.7028849","DOIUrl":null,"url":null,"abstract":"All distributed generating units need to be equipped with an anti-islanding (AI) protection scheme in order to avoid unintentional islanding. Unfortunately most AI methods fail to detect islanding when the islanded load matches with the production in the island. Another concerning issue is that certain active AI protection schemes may cause power quality problems. This paper proposes an AI protection method which is based on the combination of a specially designed reactive power versus frequency (Q-f) droop, and a constantly injected reactive power variation (RPV) pulse. The method is designed so that the injection of reactive power is of minor scale during normal operating conditions. Yet, the method shows high performance during islanding. Simulations were performed with the help of PSCAD/EMTDC in order to analyze the performance of the method. The results indicate that the method is able to detect islanding within 2 seconds even in a perfectly balanced island.","PeriodicalId":299515,"journal":{"name":"IEEE PES Innovative Smart Grid Technologies, Europe","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A novel anti-islanding protection method based on the combination of a Q-f droop and RPV\",\"authors\":\"O. Raipala, A. Makinen, S. Repo, P. Jarventausta\",\"doi\":\"10.1109/ISGTEUROPE.2014.7028849\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"All distributed generating units need to be equipped with an anti-islanding (AI) protection scheme in order to avoid unintentional islanding. Unfortunately most AI methods fail to detect islanding when the islanded load matches with the production in the island. Another concerning issue is that certain active AI protection schemes may cause power quality problems. This paper proposes an AI protection method which is based on the combination of a specially designed reactive power versus frequency (Q-f) droop, and a constantly injected reactive power variation (RPV) pulse. The method is designed so that the injection of reactive power is of minor scale during normal operating conditions. Yet, the method shows high performance during islanding. Simulations were performed with the help of PSCAD/EMTDC in order to analyze the performance of the method. The results indicate that the method is able to detect islanding within 2 seconds even in a perfectly balanced island.\",\"PeriodicalId\":299515,\"journal\":{\"name\":\"IEEE PES Innovative Smart Grid Technologies, Europe\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE PES Innovative Smart Grid Technologies, Europe\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEUROPE.2014.7028849\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES Innovative Smart Grid Technologies, Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEUROPE.2014.7028849","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

所有分布式发电机组都需要配备防孤岛保护方案,以避免意外孤岛。不幸的是,大多数人工智能方法无法在孤岛负载与孤岛生产相匹配时检测到孤岛。另一个值得关注的问题是,某些主动人工智能保护方案可能会导致电能质量问题。本文提出了一种基于特殊设计的无功功率随频率(Q-f)下垂和持续注入无功功率变化(RPV)脉冲相结合的人工智能保护方法。该方法的设计目的是使在正常运行条件下注入的无功功率规模较小。然而,该方法在孤岛过程中表现出较高的性能。利用PSCAD/EMTDC进行了仿真,分析了该方法的性能。结果表明,即使在完全平衡的孤岛上,该方法也能在2秒内检测到孤岛。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel anti-islanding protection method based on the combination of a Q-f droop and RPV
All distributed generating units need to be equipped with an anti-islanding (AI) protection scheme in order to avoid unintentional islanding. Unfortunately most AI methods fail to detect islanding when the islanded load matches with the production in the island. Another concerning issue is that certain active AI protection schemes may cause power quality problems. This paper proposes an AI protection method which is based on the combination of a specially designed reactive power versus frequency (Q-f) droop, and a constantly injected reactive power variation (RPV) pulse. The method is designed so that the injection of reactive power is of minor scale during normal operating conditions. Yet, the method shows high performance during islanding. Simulations were performed with the help of PSCAD/EMTDC in order to analyze the performance of the method. The results indicate that the method is able to detect islanding within 2 seconds even in a perfectly balanced island.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信