{"title":"温度对NDIR气体分析仪信噪比影响的研究","authors":"Hongmei Liu, Chuanwu Tan","doi":"10.1109/ICVRIS51417.2020.00121","DOIUrl":null,"url":null,"abstract":"In order to improve the signal-to-noise ratio of the non spectroscopic infrared gas analyzer and analyze the influence of the temperature stability in the infrared pool on the absorption of the gas, this paper makes a comparative test on the non spectroscopic infrared gas analyzer in the room temperature and constant temperature control environment. In the experiment, the high-precision constant temperature system with incremental PID algorithm is used to control the constant temperature point at 48 ± 0.1 °C, which is shown by the test comparison under the high-precision constant temperature system, The signal-to-noise ratio of the gas analyzer is improved obviously.","PeriodicalId":162549,"journal":{"name":"2020 International Conference on Virtual Reality and Intelligent Systems (ICVRIS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on the effect of temperature on the ratio of signal to noise for NDIR gas analyzer\",\"authors\":\"Hongmei Liu, Chuanwu Tan\",\"doi\":\"10.1109/ICVRIS51417.2020.00121\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to improve the signal-to-noise ratio of the non spectroscopic infrared gas analyzer and analyze the influence of the temperature stability in the infrared pool on the absorption of the gas, this paper makes a comparative test on the non spectroscopic infrared gas analyzer in the room temperature and constant temperature control environment. In the experiment, the high-precision constant temperature system with incremental PID algorithm is used to control the constant temperature point at 48 ± 0.1 °C, which is shown by the test comparison under the high-precision constant temperature system, The signal-to-noise ratio of the gas analyzer is improved obviously.\",\"PeriodicalId\":162549,\"journal\":{\"name\":\"2020 International Conference on Virtual Reality and Intelligent Systems (ICVRIS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Conference on Virtual Reality and Intelligent Systems (ICVRIS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICVRIS51417.2020.00121\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Conference on Virtual Reality and Intelligent Systems (ICVRIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICVRIS51417.2020.00121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study on the effect of temperature on the ratio of signal to noise for NDIR gas analyzer
In order to improve the signal-to-noise ratio of the non spectroscopic infrared gas analyzer and analyze the influence of the temperature stability in the infrared pool on the absorption of the gas, this paper makes a comparative test on the non spectroscopic infrared gas analyzer in the room temperature and constant temperature control environment. In the experiment, the high-precision constant temperature system with incremental PID algorithm is used to control the constant temperature point at 48 ± 0.1 °C, which is shown by the test comparison under the high-precision constant temperature system, The signal-to-noise ratio of the gas analyzer is improved obviously.