一种磁耦合再生开关缓冲器配置[用于升压变换器]

P.J.M. Menegaz, J.L.F. Vieira, D. Simonetti
{"title":"一种磁耦合再生开关缓冲器配置[用于升压变换器]","authors":"P.J.M. Menegaz, J.L.F. Vieira, D. Simonetti","doi":"10.1109/IECON.1997.672071","DOIUrl":null,"url":null,"abstract":"This paper presents a magnetically coupled regenerative turn-on and turn-off snubber configuration applied to a boost power converter which operates in the continuous conduction mode (CCM). In addition to reducing the stresses in the switch, providing soft transitions in its turn-off voltage and turn-on current, it transfers the entered stored in the snubber capacitor to the load. This is achieved by using a coupled inductor mounted on the main inductor of the power converter, which resets the capacitor voltage at each switching period. Design equations, as well as experimental results, are presented, showing the high efficiency of the boost power converter by using the proposed snubber.","PeriodicalId":404447,"journal":{"name":"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A magnetically coupled regenerative turn-on and turn-off snubber configuration [for boost convertor]\",\"authors\":\"P.J.M. Menegaz, J.L.F. Vieira, D. Simonetti\",\"doi\":\"10.1109/IECON.1997.672071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a magnetically coupled regenerative turn-on and turn-off snubber configuration applied to a boost power converter which operates in the continuous conduction mode (CCM). In addition to reducing the stresses in the switch, providing soft transitions in its turn-off voltage and turn-on current, it transfers the entered stored in the snubber capacitor to the load. This is achieved by using a coupled inductor mounted on the main inductor of the power converter, which resets the capacitor voltage at each switching period. Design equations, as well as experimental results, are presented, showing the high efficiency of the boost power converter by using the proposed snubber.\",\"PeriodicalId\":404447,\"journal\":{\"name\":\"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1997.672071\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1997.672071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种应用于连续导通模式(CCM)的升压功率变换器的磁耦合再生通断缓冲器结构。除了减少开关中的应力,在关断电压和通断电流中提供软转换外,它还将存储在缓冲电容器中的输入传输到负载。这是通过使用安装在功率转换器主电感上的耦合电感来实现的,该电感在每个开关周期重置电容器电压。文中给出了设计方程和实验结果,表明采用该缓冲器的升压功率变换器具有很高的效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A magnetically coupled regenerative turn-on and turn-off snubber configuration [for boost convertor]
This paper presents a magnetically coupled regenerative turn-on and turn-off snubber configuration applied to a boost power converter which operates in the continuous conduction mode (CCM). In addition to reducing the stresses in the switch, providing soft transitions in its turn-off voltage and turn-on current, it transfers the entered stored in the snubber capacitor to the load. This is achieved by using a coupled inductor mounted on the main inductor of the power converter, which resets the capacitor voltage at each switching period. Design equations, as well as experimental results, are presented, showing the high efficiency of the boost power converter by using the proposed snubber.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信