Liang Xuan, Xuan Yang, Wenxiong Hong, T. Guan, Hengheng Jiang
{"title":"FT针针摆线传动几何传动精度实验研究","authors":"Liang Xuan, Xuan Yang, Wenxiong Hong, T. Guan, Hengheng Jiang","doi":"10.1109/ICMAE52228.2021.9522532","DOIUrl":null,"url":null,"abstract":"Pin-Cycloid planetary reducer is mostly used in high precision transmission. It has extremely strict requirements on transmission accuracy. Transmission accuracy and rotation error measurement are important experimental parameters for the pin-cycloid planetary reducer transmission performance. In this paper, the experimental table and related transmission components are designed according to the FT455 reducer relevant parameters. The transmission precision and the rotation error of the whole prototype are tested and the results of the experiment are analyzed. At the same time, it is proved that the calculation procedure of the transmission precision and the rotation error for the FT pin-cycloid transmission are correct.","PeriodicalId":161846,"journal":{"name":"2021 12th International Conference on Mechanical and Aerospace Engineering (ICMAE)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Geometric Transmission Precision Experiment for FT Pin-Cycloid Transmission\",\"authors\":\"Liang Xuan, Xuan Yang, Wenxiong Hong, T. Guan, Hengheng Jiang\",\"doi\":\"10.1109/ICMAE52228.2021.9522532\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pin-Cycloid planetary reducer is mostly used in high precision transmission. It has extremely strict requirements on transmission accuracy. Transmission accuracy and rotation error measurement are important experimental parameters for the pin-cycloid planetary reducer transmission performance. In this paper, the experimental table and related transmission components are designed according to the FT455 reducer relevant parameters. The transmission precision and the rotation error of the whole prototype are tested and the results of the experiment are analyzed. At the same time, it is proved that the calculation procedure of the transmission precision and the rotation error for the FT pin-cycloid transmission are correct.\",\"PeriodicalId\":161846,\"journal\":{\"name\":\"2021 12th International Conference on Mechanical and Aerospace Engineering (ICMAE)\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 12th International Conference on Mechanical and Aerospace Engineering (ICMAE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMAE52228.2021.9522532\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 12th International Conference on Mechanical and Aerospace Engineering (ICMAE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMAE52228.2021.9522532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on Geometric Transmission Precision Experiment for FT Pin-Cycloid Transmission
Pin-Cycloid planetary reducer is mostly used in high precision transmission. It has extremely strict requirements on transmission accuracy. Transmission accuracy and rotation error measurement are important experimental parameters for the pin-cycloid planetary reducer transmission performance. In this paper, the experimental table and related transmission components are designed according to the FT455 reducer relevant parameters. The transmission precision and the rotation error of the whole prototype are tested and the results of the experiment are analyzed. At the same time, it is proved that the calculation procedure of the transmission precision and the rotation error for the FT pin-cycloid transmission are correct.