{"title":"变压器老化性能研究现状油绝缘研究现状","authors":"Nisha Thanua, Ganesh Balu Kumbhar","doi":"10.1109/catcon52335.2021.9670470","DOIUrl":null,"url":null,"abstract":"The objective of this review paper is to understand the aging aspects of the transformer insulating oil by studying the aging performance of two widely used liquid dielectrics ie., mineral oil and natural ester oils along with paper as solid insulation. The performance of the power transformer is mainly decided by the proper working of its insulation. Thus monitoring the performance of insulating oil with aging results in more reliable working of the transformers. Here the aging mechanism of the insulating oil is briefly discussed alongside various study done in understanding the aging performance of both the liquid dielectrics using various methods and thus the degradation rate of both the dielectrics are examined. Naturally available ester oils are found to have better performance in comparison to mineral oil and also the paper degradation rate was found to be slower in these ester oils. Various methods used in monitoring the aging phenomenon are discussed briefly which compares the aging markers of both the oils.","PeriodicalId":162130,"journal":{"name":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Aging Performance of Transformer State of Art Review Oil Insulation- State of Art Review\",\"authors\":\"Nisha Thanua, Ganesh Balu Kumbhar\",\"doi\":\"10.1109/catcon52335.2021.9670470\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this review paper is to understand the aging aspects of the transformer insulating oil by studying the aging performance of two widely used liquid dielectrics ie., mineral oil and natural ester oils along with paper as solid insulation. The performance of the power transformer is mainly decided by the proper working of its insulation. Thus monitoring the performance of insulating oil with aging results in more reliable working of the transformers. Here the aging mechanism of the insulating oil is briefly discussed alongside various study done in understanding the aging performance of both the liquid dielectrics using various methods and thus the degradation rate of both the dielectrics are examined. Naturally available ester oils are found to have better performance in comparison to mineral oil and also the paper degradation rate was found to be slower in these ester oils. Various methods used in monitoring the aging phenomenon are discussed briefly which compares the aging markers of both the oils.\",\"PeriodicalId\":162130,\"journal\":{\"name\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/catcon52335.2021.9670470\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/catcon52335.2021.9670470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文的目的是通过研究两种广泛使用的液体介电介质即绝缘油的老化性能来了解变压器绝缘油的老化问题。、矿物油和天然酯类油与纸张一起作为固体绝缘材料。电力变压器的性能主要取决于其绝缘工作的好坏。因此,对老化绝缘油的性能进行监测,可以使变压器更加可靠地工作。本文简要讨论了绝缘油的老化机理,并采用各种方法对两种液体介质的老化性能进行了研究,从而对两种介质的降解率进行了研究。与矿物油相比,天然可用的酯油具有更好的性能,而且这些酯油的纸张降解速度也较慢。简要讨论了用于监测油品老化现象的各种方法,并对两种油品的老化标志进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Aging Performance of Transformer State of Art Review Oil Insulation- State of Art Review
The objective of this review paper is to understand the aging aspects of the transformer insulating oil by studying the aging performance of two widely used liquid dielectrics ie., mineral oil and natural ester oils along with paper as solid insulation. The performance of the power transformer is mainly decided by the proper working of its insulation. Thus monitoring the performance of insulating oil with aging results in more reliable working of the transformers. Here the aging mechanism of the insulating oil is briefly discussed alongside various study done in understanding the aging performance of both the liquid dielectrics using various methods and thus the degradation rate of both the dielectrics are examined. Naturally available ester oils are found to have better performance in comparison to mineral oil and also the paper degradation rate was found to be slower in these ester oils. Various methods used in monitoring the aging phenomenon are discussed briefly which compares the aging markers of both the oils.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信