{"title":"屏蔽罩半消声室重建关键问题探讨","authors":"Rui Chen, Jianxuan Li, Yong Zhang, Chunquan He","doi":"10.1109/CSRSWTC50769.2020.9372455","DOIUrl":null,"url":null,"abstract":"In this paper, some problems are discussed on the reconstruction of semi-anechoic chamber in a non-standard size shielding enclosure, such as structural, grounding, lighting, ventilation system and selection of shielding material. The reconstructed semi-anechoic chamber has good performance, the two indicators of shielding effectiveness and background noise meet the requirement in GJB151A-1997 and GJB151B-2013, EMC test can be conducted in the new semi-anechoic chamber. It is feasible and cost-effective to transform a non-standard size old shielding enclosure into a semi-anechoic chamber. This paper has some reference for the similar transformation needs.","PeriodicalId":207010,"journal":{"name":"2020 Cross Strait Radio Science & Wireless Technology Conference (CSRSWTC)","volume":"300 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Discussion of Key Problems on Reconstruction of Semi-anechoic Chamber in a Shielding Enclosure\",\"authors\":\"Rui Chen, Jianxuan Li, Yong Zhang, Chunquan He\",\"doi\":\"10.1109/CSRSWTC50769.2020.9372455\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, some problems are discussed on the reconstruction of semi-anechoic chamber in a non-standard size shielding enclosure, such as structural, grounding, lighting, ventilation system and selection of shielding material. The reconstructed semi-anechoic chamber has good performance, the two indicators of shielding effectiveness and background noise meet the requirement in GJB151A-1997 and GJB151B-2013, EMC test can be conducted in the new semi-anechoic chamber. It is feasible and cost-effective to transform a non-standard size old shielding enclosure into a semi-anechoic chamber. This paper has some reference for the similar transformation needs.\",\"PeriodicalId\":207010,\"journal\":{\"name\":\"2020 Cross Strait Radio Science & Wireless Technology Conference (CSRSWTC)\",\"volume\":\"300 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Cross Strait Radio Science & Wireless Technology Conference (CSRSWTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CSRSWTC50769.2020.9372455\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Cross Strait Radio Science & Wireless Technology Conference (CSRSWTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CSRSWTC50769.2020.9372455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Discussion of Key Problems on Reconstruction of Semi-anechoic Chamber in a Shielding Enclosure
In this paper, some problems are discussed on the reconstruction of semi-anechoic chamber in a non-standard size shielding enclosure, such as structural, grounding, lighting, ventilation system and selection of shielding material. The reconstructed semi-anechoic chamber has good performance, the two indicators of shielding effectiveness and background noise meet the requirement in GJB151A-1997 and GJB151B-2013, EMC test can be conducted in the new semi-anechoic chamber. It is feasible and cost-effective to transform a non-standard size old shielding enclosure into a semi-anechoic chamber. This paper has some reference for the similar transformation needs.