瞬态故障下COTS DBMS鲁棒性的实验评估

D. Costa, H. Madeira
{"title":"瞬态故障下COTS DBMS鲁棒性的实验评估","authors":"D. Costa, H. Madeira","doi":"10.1109/PRDC.1999.816230","DOIUrl":null,"url":null,"abstract":"This paper evaluates the behavior of a common off-the-shelf (COTS) database management system (DBMS) in presence of transient faults. Database applications have traditionally been a field with fault-tolerance needs, concerning both data integrity and availability. While most of the commercially available DBMS provide support for data recovery and fault-tolerance, very limited knowledge was available regarding the impact of transient faults in a COTS database system. In this experimental study, a strict off-the-shelf target system is used (Oracle 7.3 server running on top of Wintel platform), combined with a TPC-A based workload and a software implemented fault injection tool, XceptionNT. It was found out that a non-negligible amount of induced faults, 13%, lead to the database server hanging or premature termination. However, the results also show that COTS DBMS products has a reasonable behavior concerning data integrity, none of the injected faults affected end user data.","PeriodicalId":389294,"journal":{"name":"Proceedings 1999 Pacific Rim International Symposium on Dependable Computing","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Experimental assessment of COTS DBMS robustness under transient faults\",\"authors\":\"D. Costa, H. Madeira\",\"doi\":\"10.1109/PRDC.1999.816230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper evaluates the behavior of a common off-the-shelf (COTS) database management system (DBMS) in presence of transient faults. Database applications have traditionally been a field with fault-tolerance needs, concerning both data integrity and availability. While most of the commercially available DBMS provide support for data recovery and fault-tolerance, very limited knowledge was available regarding the impact of transient faults in a COTS database system. In this experimental study, a strict off-the-shelf target system is used (Oracle 7.3 server running on top of Wintel platform), combined with a TPC-A based workload and a software implemented fault injection tool, XceptionNT. It was found out that a non-negligible amount of induced faults, 13%, lead to the database server hanging or premature termination. However, the results also show that COTS DBMS products has a reasonable behavior concerning data integrity, none of the injected faults affected end user data.\",\"PeriodicalId\":389294,\"journal\":{\"name\":\"Proceedings 1999 Pacific Rim International Symposium on Dependable Computing\",\"volume\":\"58 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings 1999 Pacific Rim International Symposium on Dependable Computing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PRDC.1999.816230\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 1999 Pacific Rim International Symposium on Dependable Computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PRDC.1999.816230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文评估了一种常见的现成数据库管理系统(COTS)在存在暂态故障时的行为。数据库应用程序传统上是一个需要容错的领域,涉及数据完整性和可用性。虽然大多数商业上可用的DBMS都提供数据恢复和容错支持,但是关于COTS数据库系统中瞬态故障的影响的知识非常有限。在本实验研究中,使用了一个严格的现成目标系统(运行在Wintel平台上的Oracle 7.3服务器),结合基于TPC-A的工作负载和软件实现的故障注入工具XceptionNT。结果发现,13%的诱发性故障导致数据库服务器挂起或过早终止。然而,结果也表明,COTS DBMS产品在数据完整性方面具有合理的行为,注入的错误没有影响最终用户的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental assessment of COTS DBMS robustness under transient faults
This paper evaluates the behavior of a common off-the-shelf (COTS) database management system (DBMS) in presence of transient faults. Database applications have traditionally been a field with fault-tolerance needs, concerning both data integrity and availability. While most of the commercially available DBMS provide support for data recovery and fault-tolerance, very limited knowledge was available regarding the impact of transient faults in a COTS database system. In this experimental study, a strict off-the-shelf target system is used (Oracle 7.3 server running on top of Wintel platform), combined with a TPC-A based workload and a software implemented fault injection tool, XceptionNT. It was found out that a non-negligible amount of induced faults, 13%, lead to the database server hanging or premature termination. However, the results also show that COTS DBMS products has a reasonable behavior concerning data integrity, none of the injected faults affected end user data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信