{"title":"空气传导的滴答声和声脉冲听觉脑干反应刺激的行为和电声校准","authors":"Mridula Sharma, S. Purdy, Lou Bonnici","doi":"10.1375/AUDI.25.1.54.31122","DOIUrl":null,"url":null,"abstract":"Although auditory brainstem response (ABR) audiometry is widely used to assess hearing sensitivity in infants and young children, normal calibration values vary across clinics. This study was undertaken to determine normal hearing thresholds for tonebursts and clicks with insert earphones. Techniques for performing electroacoustic and behavioural calibration of brief ABR stimuli are described. The average insert earphone thresholds for 25 young adults with normal hearing for 500, 1000, 2000, 4000 and 8000 Hz, 2-1-2 cycle tonebursts presented at 41 per second were: 24, 20, 23, 23 and 34 dB peak to peak equivalent (ppe) SPL (re 20 Pa), respectively. Average thresholds were about 30 dB ppeSPL for 100 s clicks. Results were generally consistent with normative values reported in the literature.","PeriodicalId":114768,"journal":{"name":"Australian and New Zealand Journal of Audiology","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Behavioural and Electroacoustic Calibration of Air-conducted Click and Toneburst Auditory Brainstem Response Stimuli\",\"authors\":\"Mridula Sharma, S. Purdy, Lou Bonnici\",\"doi\":\"10.1375/AUDI.25.1.54.31122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Although auditory brainstem response (ABR) audiometry is widely used to assess hearing sensitivity in infants and young children, normal calibration values vary across clinics. This study was undertaken to determine normal hearing thresholds for tonebursts and clicks with insert earphones. Techniques for performing electroacoustic and behavioural calibration of brief ABR stimuli are described. The average insert earphone thresholds for 25 young adults with normal hearing for 500, 1000, 2000, 4000 and 8000 Hz, 2-1-2 cycle tonebursts presented at 41 per second were: 24, 20, 23, 23 and 34 dB peak to peak equivalent (ppe) SPL (re 20 Pa), respectively. Average thresholds were about 30 dB ppeSPL for 100 s clicks. Results were generally consistent with normative values reported in the literature.\",\"PeriodicalId\":114768,\"journal\":{\"name\":\"Australian and New Zealand Journal of Audiology\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australian and New Zealand Journal of Audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1375/AUDI.25.1.54.31122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian and New Zealand Journal of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1375/AUDI.25.1.54.31122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
虽然听觉脑干反应(ABR)听力学被广泛用于婴幼儿的听力敏感性评估,但各诊所的正常校准值各不相同。这项研究是为了确定正常的听力阈值的音调爆发和点击与插入式耳机。描述了进行简短ABR刺激的电声和行为校准的技术。25名听力正常的年轻人在500、1000、2000、4000和8000hz、2-1-2周期、41 / s频率下的平均插入式耳机阈值分别为:24、20、23、23和34 dB峰对峰等效(ppe)声压级(约20 Pa)。点击100秒的平均阈值约为30 dB ppeSPL。结果与文献报道的正常值大体一致。
Behavioural and Electroacoustic Calibration of Air-conducted Click and Toneburst Auditory Brainstem Response Stimuli
Although auditory brainstem response (ABR) audiometry is widely used to assess hearing sensitivity in infants and young children, normal calibration values vary across clinics. This study was undertaken to determine normal hearing thresholds for tonebursts and clicks with insert earphones. Techniques for performing electroacoustic and behavioural calibration of brief ABR stimuli are described. The average insert earphone thresholds for 25 young adults with normal hearing for 500, 1000, 2000, 4000 and 8000 Hz, 2-1-2 cycle tonebursts presented at 41 per second were: 24, 20, 23, 23 and 34 dB peak to peak equivalent (ppe) SPL (re 20 Pa), respectively. Average thresholds were about 30 dB ppeSPL for 100 s clicks. Results were generally consistent with normative values reported in the literature.