采用IEC 61850的智能配电总线自动传输方案

Balaji Guddanti, Genesis Alvarez, Nilesh Bilimoria, Xiawen Lit, Micah J. Till
{"title":"采用IEC 61850的智能配电总线自动传输方案","authors":"Balaji Guddanti, Genesis Alvarez, Nilesh Bilimoria, Xiawen Lit, Micah J. Till","doi":"10.1109/IAS54023.2022.9939869","DOIUrl":null,"url":null,"abstract":"An automatic bus transfer scheme (ABTS) is a conventional method of supplying power to a load by safely transferring motor loads to an alternate healthy source if the primary source fails. State-of-the-art bus transfer schemes can be improved significantly by using intelligent electronic devices (IEDs) and communication standard IEC 61850 to supply uninterrupted power to customers. In this work, an intelligent distribution bus automatic transfer scheme (IDBATS) is proposed, which leverages the use of generic object-oriented substation event (GOOSE) messages. The scheme prevents the power transformer from overloading, and it can be implemented on a substation regardless of the network configuration and load demand. Since the protection logic is kept in the master IED, the scheme can include any new transformers added to the substation network. The IDBATS scheme was validated on a 230 kV/34.5 kV distribution substation by conducting a hardware-in-the-loop simulation using real-time digital simulator (RTDS).","PeriodicalId":193587,"journal":{"name":"2022 IEEE Industry Applications Society Annual Meeting (IAS)","volume":"30 21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intelligent Distribution Bus Automatic Transfer Scheme using IEC 61850\",\"authors\":\"Balaji Guddanti, Genesis Alvarez, Nilesh Bilimoria, Xiawen Lit, Micah J. Till\",\"doi\":\"10.1109/IAS54023.2022.9939869\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An automatic bus transfer scheme (ABTS) is a conventional method of supplying power to a load by safely transferring motor loads to an alternate healthy source if the primary source fails. State-of-the-art bus transfer schemes can be improved significantly by using intelligent electronic devices (IEDs) and communication standard IEC 61850 to supply uninterrupted power to customers. In this work, an intelligent distribution bus automatic transfer scheme (IDBATS) is proposed, which leverages the use of generic object-oriented substation event (GOOSE) messages. The scheme prevents the power transformer from overloading, and it can be implemented on a substation regardless of the network configuration and load demand. Since the protection logic is kept in the master IED, the scheme can include any new transformers added to the substation network. The IDBATS scheme was validated on a 230 kV/34.5 kV distribution substation by conducting a hardware-in-the-loop simulation using real-time digital simulator (RTDS).\",\"PeriodicalId\":193587,\"journal\":{\"name\":\"2022 IEEE Industry Applications Society Annual Meeting (IAS)\",\"volume\":\"30 21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE Industry Applications Society Annual Meeting (IAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS54023.2022.9939869\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Industry Applications Society Annual Meeting (IAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS54023.2022.9939869","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

自动母线转移方案(ABTS)是一种传统的供电方法,当主电源发生故障时,将电机负载安全地转移到备用健康电源上。通过使用智能电子设备(ied)和通信标准IEC 61850为客户提供不间断的电力,可以显著改善最先进的总线传输方案。在这项工作中,提出了一种智能配电总线自动传输方案(IDBATS),该方案利用了通用面向对象变电站事件(GOOSE)消息的使用。该方案可防止电力变压器过载,且无论网络配置和负荷需求如何,均可在变电站上实现。由于保护逻辑保存在主IED中,因此该方案可以包括添加到变电站网络中的任何新变压器。利用实时数字模拟器(RTDS)对一个230 kV/34.5 kV配电变电所进行了硬件在环仿真,验证了IDBATS方案的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intelligent Distribution Bus Automatic Transfer Scheme using IEC 61850
An automatic bus transfer scheme (ABTS) is a conventional method of supplying power to a load by safely transferring motor loads to an alternate healthy source if the primary source fails. State-of-the-art bus transfer schemes can be improved significantly by using intelligent electronic devices (IEDs) and communication standard IEC 61850 to supply uninterrupted power to customers. In this work, an intelligent distribution bus automatic transfer scheme (IDBATS) is proposed, which leverages the use of generic object-oriented substation event (GOOSE) messages. The scheme prevents the power transformer from overloading, and it can be implemented on a substation regardless of the network configuration and load demand. Since the protection logic is kept in the master IED, the scheme can include any new transformers added to the substation network. The IDBATS scheme was validated on a 230 kV/34.5 kV distribution substation by conducting a hardware-in-the-loop simulation using real-time digital simulator (RTDS).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信