汽车用电容式液位计的设计

Qingliang Zhang
{"title":"汽车用电容式液位计的设计","authors":"Qingliang Zhang","doi":"10.1109/ICEDIF.2015.7280196","DOIUrl":null,"url":null,"abstract":"The measurement methods of liquid level are summarized. A cylindrical tube capacitive liquidometer consisting of two tubes is produced. Arithmetic relationship between the liquid level and the capacitance is derived. AD7746 is used to convert the capacitance signal into voltage signal. The voltage signal is then processed by PIC16F877 microcontroller and digitally displayed by the circuit of 1602. It is stated that sensor errors lie in manufacture, structure, and liquid temperature changes. The corresponding solutions are put forward. The calibration is carried out on the instrument to compare the values of the standard capacitance and calculated capacitance and test results are given.","PeriodicalId":355975,"journal":{"name":"2015 International Conference on Estimation, Detection and Information Fusion (ICEDIF)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Design of a capacitive liquidometer applied in automobile\",\"authors\":\"Qingliang Zhang\",\"doi\":\"10.1109/ICEDIF.2015.7280196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The measurement methods of liquid level are summarized. A cylindrical tube capacitive liquidometer consisting of two tubes is produced. Arithmetic relationship between the liquid level and the capacitance is derived. AD7746 is used to convert the capacitance signal into voltage signal. The voltage signal is then processed by PIC16F877 microcontroller and digitally displayed by the circuit of 1602. It is stated that sensor errors lie in manufacture, structure, and liquid temperature changes. The corresponding solutions are put forward. The calibration is carried out on the instrument to compare the values of the standard capacitance and calculated capacitance and test results are given.\",\"PeriodicalId\":355975,\"journal\":{\"name\":\"2015 International Conference on Estimation, Detection and Information Fusion (ICEDIF)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Estimation, Detection and Information Fusion (ICEDIF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEDIF.2015.7280196\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Estimation, Detection and Information Fusion (ICEDIF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEDIF.2015.7280196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

对液位的测量方法进行了总结。研制了一种由两根管组成的圆柱形管电容式液体计。推导了液面与电容之间的算术关系。AD7746用于将电容信号转换为电压信号。电压信号经PIC16F877单片机处理后,由1602电路数字显示。指出传感器误差存在于制造、结构和液体温度变化等方面。并提出了相应的解决方案。对仪器进行了标定,比较了标准电容值和计算电容值,并给出了测试结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of a capacitive liquidometer applied in automobile
The measurement methods of liquid level are summarized. A cylindrical tube capacitive liquidometer consisting of two tubes is produced. Arithmetic relationship between the liquid level and the capacitance is derived. AD7746 is used to convert the capacitance signal into voltage signal. The voltage signal is then processed by PIC16F877 microcontroller and digitally displayed by the circuit of 1602. It is stated that sensor errors lie in manufacture, structure, and liquid temperature changes. The corresponding solutions are put forward. The calibration is carried out on the instrument to compare the values of the standard capacitance and calculated capacitance and test results are given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信