{"title":"表面等离子体共振传感器在医学诊断中的红血细胞大小分布分析","authors":"Tania Das, N. Das","doi":"10.1109/ICECI.2014.6767388","DOIUrl":null,"url":null,"abstract":"The paper provides an analysis of different sizes red blood corpuscles (RBC) using surface Plasmon resonance (SPR) sensor. Change of RBC size affects the change of refractive index. SPR sensor is sensitive towards this small change of refractive index. A general formula is given in this paper such that just observing the output intensity of SPR sensor, the size of the RBC present as dielectric at the interface of metal in SPR sensor can be determined.","PeriodicalId":315219,"journal":{"name":"International Conference on Electronics, Communication and Instrumentation (ICECI)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of size distribution of red blood corpuscles using surface Plasmon resonance sensor for medical diagnosis\",\"authors\":\"Tania Das, N. Das\",\"doi\":\"10.1109/ICECI.2014.6767388\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper provides an analysis of different sizes red blood corpuscles (RBC) using surface Plasmon resonance (SPR) sensor. Change of RBC size affects the change of refractive index. SPR sensor is sensitive towards this small change of refractive index. A general formula is given in this paper such that just observing the output intensity of SPR sensor, the size of the RBC present as dielectric at the interface of metal in SPR sensor can be determined.\",\"PeriodicalId\":315219,\"journal\":{\"name\":\"International Conference on Electronics, Communication and Instrumentation (ICECI)\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Electronics, Communication and Instrumentation (ICECI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECI.2014.6767388\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Electronics, Communication and Instrumentation (ICECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECI.2014.6767388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of size distribution of red blood corpuscles using surface Plasmon resonance sensor for medical diagnosis
The paper provides an analysis of different sizes red blood corpuscles (RBC) using surface Plasmon resonance (SPR) sensor. Change of RBC size affects the change of refractive index. SPR sensor is sensitive towards this small change of refractive index. A general formula is given in this paper such that just observing the output intensity of SPR sensor, the size of the RBC present as dielectric at the interface of metal in SPR sensor can be determined.