{"title":"可变开关频率和不连续输入电流下的单开关三相功率因数预调节器","authors":"D. Simonetti, J. Sebastián, J. Uceda","doi":"10.1109/PESC.1993.471995","DOIUrl":null,"url":null,"abstract":"A three-phase power factor preregulator with input inductor, diode bridge, and a single switch is analyzed. Operation with discontinuous input current and variable switching frequency is considered. Equations for average input current are presented, showing that quasi-sinusoidal waveforms are obtained. Also, the switching frequency equation shows an almost constant frequency operation. A design procedure is presented, where simulation and practical results show the good performance of the approach. Comparison with constant frequency operation also shows that a better harmonic distortion is obtained if the voltage in the switch (with switch off) is not far from the input voltage. Also, in this case, the high-order harmonic content is easily filtered.<<ETX>>","PeriodicalId":358822,"journal":{"name":"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"84","resultStr":"{\"title\":\"Single-switch three-phase power factor preregulator under variable switching frequency and discontinuous input current\",\"authors\":\"D. Simonetti, J. Sebastián, J. Uceda\",\"doi\":\"10.1109/PESC.1993.471995\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A three-phase power factor preregulator with input inductor, diode bridge, and a single switch is analyzed. Operation with discontinuous input current and variable switching frequency is considered. Equations for average input current are presented, showing that quasi-sinusoidal waveforms are obtained. Also, the switching frequency equation shows an almost constant frequency operation. A design procedure is presented, where simulation and practical results show the good performance of the approach. Comparison with constant frequency operation also shows that a better harmonic distortion is obtained if the voltage in the switch (with switch off) is not far from the input voltage. Also, in this case, the high-order harmonic content is easily filtered.<<ETX>>\",\"PeriodicalId\":358822,\"journal\":{\"name\":\"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"84\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1993.471995\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Power Electronics Specialist Conference - PESC '93","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1993.471995","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Single-switch three-phase power factor preregulator under variable switching frequency and discontinuous input current
A three-phase power factor preregulator with input inductor, diode bridge, and a single switch is analyzed. Operation with discontinuous input current and variable switching frequency is considered. Equations for average input current are presented, showing that quasi-sinusoidal waveforms are obtained. Also, the switching frequency equation shows an almost constant frequency operation. A design procedure is presented, where simulation and practical results show the good performance of the approach. Comparison with constant frequency operation also shows that a better harmonic distortion is obtained if the voltage in the switch (with switch off) is not far from the input voltage. Also, in this case, the high-order harmonic content is easily filtered.<>