混合UP-PWM的单相无变压器光伏逆变器改善过零失真

Zhongting Tang, M. Su, Yao Sun, Hui Wang, Bin Guo, Yunfan Yang
{"title":"混合UP-PWM的单相无变压器光伏逆变器改善过零失真","authors":"Zhongting Tang, M. Su, Yao Sun, Hui Wang, Bin Guo, Yunfan Yang","doi":"10.1109/IESES.2018.8349904","DOIUrl":null,"url":null,"abstract":"The zero-crossing distortion (ZCD) is a common problem in Single-phase transformerless photovoltaic (PV) inverter. By establishing the mathematical model of the HERIC type inverter which is proved to be a mainstream transformerless PV inverter, the result for causing the ZCD is presented. To suppressing the ZCD while achieve high efficiency and reactive power capability, a hybrid unipolar pulse width modulation (UP-PWM) is proposed. The proposed method adopts grid frequency unipolar pulse width modulation (GFUP-PWM) when outputting active power. While generating reactive power, the leg switches are all closed, and only the freewheeling switches work at high frequency. Aiming at reducing the ZCD, a modified high frequency unipolar pulse width modulation (HFUP-PWM) is proposed near the voltage and current zero-crossing point (ZCP) regions. And the duty cycle is adjusted to compensate the narrow pulse limit and dead zone in HFUP-PWM. The proposed scheme has high efficiency and good power quality while provide reactive power support. Finally, the effectiveness of the proposed modulation scheme is verified by the simulations results based on a 4-kW inverter at 20-kHz switching frequency.","PeriodicalId":146951,"journal":{"name":"2018 IEEE International Conference on Industrial Electronics for Sustainable Energy Systems (IESES)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Hybrid UP-PWM for single-phase transformerless photovoltaic inverter to improve zero-crossing distortion\",\"authors\":\"Zhongting Tang, M. Su, Yao Sun, Hui Wang, Bin Guo, Yunfan Yang\",\"doi\":\"10.1109/IESES.2018.8349904\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The zero-crossing distortion (ZCD) is a common problem in Single-phase transformerless photovoltaic (PV) inverter. By establishing the mathematical model of the HERIC type inverter which is proved to be a mainstream transformerless PV inverter, the result for causing the ZCD is presented. To suppressing the ZCD while achieve high efficiency and reactive power capability, a hybrid unipolar pulse width modulation (UP-PWM) is proposed. The proposed method adopts grid frequency unipolar pulse width modulation (GFUP-PWM) when outputting active power. While generating reactive power, the leg switches are all closed, and only the freewheeling switches work at high frequency. Aiming at reducing the ZCD, a modified high frequency unipolar pulse width modulation (HFUP-PWM) is proposed near the voltage and current zero-crossing point (ZCP) regions. And the duty cycle is adjusted to compensate the narrow pulse limit and dead zone in HFUP-PWM. The proposed scheme has high efficiency and good power quality while provide reactive power support. Finally, the effectiveness of the proposed modulation scheme is verified by the simulations results based on a 4-kW inverter at 20-kHz switching frequency.\",\"PeriodicalId\":146951,\"journal\":{\"name\":\"2018 IEEE International Conference on Industrial Electronics for Sustainable Energy Systems (IESES)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE International Conference on Industrial Electronics for Sustainable Energy Systems (IESES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IESES.2018.8349904\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Conference on Industrial Electronics for Sustainable Energy Systems (IESES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IESES.2018.8349904","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

过零失真(ZCD)是单相无变压器光伏(PV)逆变器中常见的问题。通过建立HERIC型无变压器光伏逆变器的数学模型,给出了产生ZCD的原因。为了在抑制ZCD的同时获得高效率和无功能力,提出了一种混合单极脉宽调制(UP-PWM)方法。该方法在输出有功功率时采用栅频单极脉宽调制(gup - pwm)。在产生无功功率时,支腿开关全部闭合,只有自由开关在高频时工作。针对降低ZCD的问题,在电压和电流过零点附近提出了一种改进的高频单极脉宽调制(hup - pwm)方法。并通过调整占空比来补偿hup - pwm的窄脉冲限和死区。该方案在提供无功支持的同时,效率高,电能质量好。最后,基于4 kw逆变器在20 khz开关频率下的仿真结果验证了所提调制方案的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hybrid UP-PWM for single-phase transformerless photovoltaic inverter to improve zero-crossing distortion
The zero-crossing distortion (ZCD) is a common problem in Single-phase transformerless photovoltaic (PV) inverter. By establishing the mathematical model of the HERIC type inverter which is proved to be a mainstream transformerless PV inverter, the result for causing the ZCD is presented. To suppressing the ZCD while achieve high efficiency and reactive power capability, a hybrid unipolar pulse width modulation (UP-PWM) is proposed. The proposed method adopts grid frequency unipolar pulse width modulation (GFUP-PWM) when outputting active power. While generating reactive power, the leg switches are all closed, and only the freewheeling switches work at high frequency. Aiming at reducing the ZCD, a modified high frequency unipolar pulse width modulation (HFUP-PWM) is proposed near the voltage and current zero-crossing point (ZCP) regions. And the duty cycle is adjusted to compensate the narrow pulse limit and dead zone in HFUP-PWM. The proposed scheme has high efficiency and good power quality while provide reactive power support. Finally, the effectiveness of the proposed modulation scheme is verified by the simulations results based on a 4-kW inverter at 20-kHz switching frequency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信