钢筋的防腐蚀屏蔽,由于混凝土中的钢纤维

A. K. Someh, N. Saeki, T. Notoya
{"title":"钢筋的防腐蚀屏蔽,由于混凝土中的钢纤维","authors":"A. K. Someh, N. Saeki, T. Notoya","doi":"10.14359/6099","DOIUrl":null,"url":null,"abstract":"Severe deterioration caused by corroding reinforcing steel in concrete structures is a major concern in the maintenance of safe and reliable infrastructure. The corrosion behavior of steel fibers and steel bars under two different aggressive conditions of modified ferroxyl gel reagent and wet-dry salt spray are described. In general, the results in the aggressive gel environment indicate that when steel fibers and steel bars were contacting each other, the initiation of corrosion in the steel fibers became considerable. When the steel fibers were electrically connected to the steel bars, the steel fibers tend to become the anode while the steel bars tend to become the cathode. The corrosion initiation, its propagation and the growth of the corrosion zones occurred in the steel fibers. The steel bars, set in the cathode zone, were protected by the surrounding steel fibers which formed a corrosion protective shield. This galvanic protection behavior by steel fibers was clearly observed in ferroxyl transparent gel.","PeriodicalId":109987,"journal":{"name":"SP-171: Third CANMET/ACI International Symposium on Advances in Concrete Technology","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"\\\"Corrosion Protection Shield of Steel Bars, Due to Steel Fibers in Concrete\\\"\",\"authors\":\"A. K. Someh, N. Saeki, T. Notoya\",\"doi\":\"10.14359/6099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Severe deterioration caused by corroding reinforcing steel in concrete structures is a major concern in the maintenance of safe and reliable infrastructure. The corrosion behavior of steel fibers and steel bars under two different aggressive conditions of modified ferroxyl gel reagent and wet-dry salt spray are described. In general, the results in the aggressive gel environment indicate that when steel fibers and steel bars were contacting each other, the initiation of corrosion in the steel fibers became considerable. When the steel fibers were electrically connected to the steel bars, the steel fibers tend to become the anode while the steel bars tend to become the cathode. The corrosion initiation, its propagation and the growth of the corrosion zones occurred in the steel fibers. The steel bars, set in the cathode zone, were protected by the surrounding steel fibers which formed a corrosion protective shield. This galvanic protection behavior by steel fibers was clearly observed in ferroxyl transparent gel.\",\"PeriodicalId\":109987,\"journal\":{\"name\":\"SP-171: Third CANMET/ACI International Symposium on Advances in Concrete Technology\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SP-171: Third CANMET/ACI International Symposium on Advances in Concrete Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14359/6099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-171: Third CANMET/ACI International Symposium on Advances in Concrete Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/6099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

混凝土结构中钢筋腐蚀引起的严重劣化是维护安全可靠基础设施的主要问题。研究了改性铁凝胶试剂和干湿盐雾两种不同腐蚀条件下钢纤维和钢筋的腐蚀行为。总的来说,在侵蚀凝胶环境下的结果表明,当钢纤维和钢筋相互接触时,钢纤维的腐蚀开始变得相当大。当钢纤维与钢筋电连接时,钢纤维倾向于成为阳极,而钢筋倾向于成为阴极。腐蚀发生在钢纤维中,腐蚀发生在钢纤维中,腐蚀区扩展在钢纤维中。设置在阴极区的钢筋由周围的钢纤维保护,形成了一个防腐蚀屏蔽。在铁氧基透明凝胶中可以清楚地观察到钢纤维的电保护行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
"Corrosion Protection Shield of Steel Bars, Due to Steel Fibers in Concrete"
Severe deterioration caused by corroding reinforcing steel in concrete structures is a major concern in the maintenance of safe and reliable infrastructure. The corrosion behavior of steel fibers and steel bars under two different aggressive conditions of modified ferroxyl gel reagent and wet-dry salt spray are described. In general, the results in the aggressive gel environment indicate that when steel fibers and steel bars were contacting each other, the initiation of corrosion in the steel fibers became considerable. When the steel fibers were electrically connected to the steel bars, the steel fibers tend to become the anode while the steel bars tend to become the cathode. The corrosion initiation, its propagation and the growth of the corrosion zones occurred in the steel fibers. The steel bars, set in the cathode zone, were protected by the surrounding steel fibers which formed a corrosion protective shield. This galvanic protection behavior by steel fibers was clearly observed in ferroxyl transparent gel.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信