新一代电源模块高空间分辨率绝缘缺陷定位系统的构建与验证

Junya Maki, T. Matsuzoe, M. Kozako, M. Hikita, Y. Nakamura, K. Taniguchi, Y. Ikeda, K. Okamoto
{"title":"新一代电源模块高空间分辨率绝缘缺陷定位系统的构建与验证","authors":"Junya Maki, T. Matsuzoe, M. Kozako, M. Hikita, Y. Nakamura, K. Taniguchi, Y. Ikeda, K. Okamoto","doi":"10.23919/ICEP.2019.8733578","DOIUrl":null,"url":null,"abstract":"This paper reports on construction and verification of a high space resolution partial discharge (PD) location system for the next generation power module. A novel PD location method (polarity reversion method) is proposed by calculating electromagnetic wave (EMW) propagation characteristics inside the power module using finite difference time domain (FDTD) analysis. In addition, EMW signal characteristics under AC voltage and impulse voltage application are compared. Based on these results, an automatic PD location system has been successfully constructed under the impulse voltage application.","PeriodicalId":213025,"journal":{"name":"2019 International Conference on Electronics Packaging (ICEP)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Construction and Verification of Novel Insulation Defect Location System with High Space Resolution for Next Generation Power Module\",\"authors\":\"Junya Maki, T. Matsuzoe, M. Kozako, M. Hikita, Y. Nakamura, K. Taniguchi, Y. Ikeda, K. Okamoto\",\"doi\":\"10.23919/ICEP.2019.8733578\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reports on construction and verification of a high space resolution partial discharge (PD) location system for the next generation power module. A novel PD location method (polarity reversion method) is proposed by calculating electromagnetic wave (EMW) propagation characteristics inside the power module using finite difference time domain (FDTD) analysis. In addition, EMW signal characteristics under AC voltage and impulse voltage application are compared. Based on these results, an automatic PD location system has been successfully constructed under the impulse voltage application.\",\"PeriodicalId\":213025,\"journal\":{\"name\":\"2019 International Conference on Electronics Packaging (ICEP)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Electronics Packaging (ICEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/ICEP.2019.8733578\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electronics Packaging (ICEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ICEP.2019.8733578","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文报道了用于下一代电源模块的高空间分辨率局部放电(PD)定位系统的构建与验证。利用时域有限差分法(FDTD)计算电源模块内电磁波的传播特性,提出了一种新的局部放电定位方法(极性反转法)。此外,还比较了交流电压和冲击电压下EMW信号的特性。在此基础上,成功构建了脉冲电压作用下的PD自动定位系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Construction and Verification of Novel Insulation Defect Location System with High Space Resolution for Next Generation Power Module
This paper reports on construction and verification of a high space resolution partial discharge (PD) location system for the next generation power module. A novel PD location method (polarity reversion method) is proposed by calculating electromagnetic wave (EMW) propagation characteristics inside the power module using finite difference time domain (FDTD) analysis. In addition, EMW signal characteristics under AC voltage and impulse voltage application are compared. Based on these results, an automatic PD location system has been successfully constructed under the impulse voltage application.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信