Kento Fujimori, Ning Li, Y. Sugimoto
{"title":"无创血糖监测传感器反射系数与透射系数的自由空间法灵敏度比较","authors":"Kento Fujimori, Ning Li, Y. Sugimoto","doi":"10.1109/BIBE.2017.00-25","DOIUrl":null,"url":null,"abstract":"This paper presents the comparison of sensitivity between the reflection and transmission coefficient by free space method for non-invasive blood glucose monitoring. In this study, aqueous glucose solutions with concentration values of 0, 1, 2, 3, and 4 w/v\\% have been tested. The calculation is done using formulas based on a three-layer model. The calculation results are then compared with the simulation results. Both calculation and simulation show almost the same results. The measurement of reflection and transmission coefficient is also implemented by using horn antenna. The results show that transmission coefficient is more sensitive with respect to the change of glucose concentration.","PeriodicalId":262603,"journal":{"name":"2017 IEEE 17th International Conference on Bioinformatics and Bioengineering (BIBE)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensitivity Comparison Between Reflection and Transmission Coefficient by Free Space Method for Non-Invasive Glucose Monitoring Sensor\",\"authors\":\"Kento Fujimori, Ning Li, Y. Sugimoto\",\"doi\":\"10.1109/BIBE.2017.00-25\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the comparison of sensitivity between the reflection and transmission coefficient by free space method for non-invasive blood glucose monitoring. In this study, aqueous glucose solutions with concentration values of 0, 1, 2, 3, and 4 w/v\\\\% have been tested. The calculation is done using formulas based on a three-layer model. The calculation results are then compared with the simulation results. Both calculation and simulation show almost the same results. The measurement of reflection and transmission coefficient is also implemented by using horn antenna. The results show that transmission coefficient is more sensitive with respect to the change of glucose concentration.\",\"PeriodicalId\":262603,\"journal\":{\"name\":\"2017 IEEE 17th International Conference on Bioinformatics and Bioengineering (BIBE)\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 17th International Conference on Bioinformatics and Bioengineering (BIBE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIBE.2017.00-25\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 17th International Conference on Bioinformatics and Bioengineering (BIBE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBE.2017.00-25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文比较了自由空间法在无创血糖监测中的反射系数和透射系数的灵敏度。在本研究中,测试了浓度为0、1、2、3和4 w/v %的葡萄糖水溶液。计算采用基于三层模型的公式。将计算结果与仿真结果进行了比较。计算和仿真结果基本一致。利用喇叭天线实现了反射系数和透射系数的测量。结果表明,透射系数对葡萄糖浓度的变化更为敏感。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sensitivity Comparison Between Reflection and Transmission Coefficient by Free Space Method for Non-Invasive Glucose Monitoring Sensor
This paper presents the comparison of sensitivity between the reflection and transmission coefficient by free space method for non-invasive blood glucose monitoring. In this study, aqueous glucose solutions with concentration values of 0, 1, 2, 3, and 4 w/v\% have been tested. The calculation is done using formulas based on a three-layer model. The calculation results are then compared with the simulation results. Both calculation and simulation show almost the same results. The measurement of reflection and transmission coefficient is also implemented by using horn antenna. The results show that transmission coefficient is more sensitive with respect to the change of glucose concentration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信