利用贴片天线探头测量MRI梯度线圈产生的电场

Arjama Halder, A. Attaran, W. Handler, B. Chronik
{"title":"利用贴片天线探头测量MRI梯度线圈产生的电场","authors":"Arjama Halder, A. Attaran, W. Handler, B. Chronik","doi":"10.1109/CCECE47787.2020.9255698","DOIUrl":null,"url":null,"abstract":"As a part of this work a small patch antenna probe was developed to measure the variation in the electric field produced by gradient coils within an MRI in the presence of any active implantable medical devices (AIMDs). This probe was designed, fabricated, and tested within a gradient coil mimicking dB/dt exposure platform. A 2×1 cm small patch antenna followed by an instrumentational amplifier was chosen to measure the electric fields. Probe was fabricated using a 4-layer PCB. The fabricated probe was used to monitor the electric fields within the phantom in the gradient coil environment. To verify the observed behavior of the probe a simulation study was performed using Sim4Life. This study aims to assess the performance of this probe in a tissue mimicking environment within the coil.","PeriodicalId":296506,"journal":{"name":"2020 IEEE Canadian Conference on Electrical and Computer Engineering (CCECE)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Measuring Electric Fields Produced by MRI Gradient Coils Using a Patch Antenna Probe\",\"authors\":\"Arjama Halder, A. Attaran, W. Handler, B. Chronik\",\"doi\":\"10.1109/CCECE47787.2020.9255698\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As a part of this work a small patch antenna probe was developed to measure the variation in the electric field produced by gradient coils within an MRI in the presence of any active implantable medical devices (AIMDs). This probe was designed, fabricated, and tested within a gradient coil mimicking dB/dt exposure platform. A 2×1 cm small patch antenna followed by an instrumentational amplifier was chosen to measure the electric fields. Probe was fabricated using a 4-layer PCB. The fabricated probe was used to monitor the electric fields within the phantom in the gradient coil environment. To verify the observed behavior of the probe a simulation study was performed using Sim4Life. This study aims to assess the performance of this probe in a tissue mimicking environment within the coil.\",\"PeriodicalId\":296506,\"journal\":{\"name\":\"2020 IEEE Canadian Conference on Electrical and Computer Engineering (CCECE)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Canadian Conference on Electrical and Computer Engineering (CCECE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCECE47787.2020.9255698\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Canadian Conference on Electrical and Computer Engineering (CCECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCECE47787.2020.9255698","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

作为这项工作的一部分,一种小型贴片天线探头被开发出来,用于测量任何有源植入式医疗设备(aimd)存在时MRI内梯度线圈产生的电场变化。该探头是在模拟dB/dt暴露平台的梯度线圈中设计、制造和测试的。选择了一个2×1 cm的小贴片天线和一个仪器放大器来测量电场。探头采用4层PCB制作。利用该探针对梯度线圈环境下的电场进行了监测。为了验证观察到的探针行为,使用Sim4Life进行了模拟研究。本研究旨在评估该探针在线圈内组织模拟环境中的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measuring Electric Fields Produced by MRI Gradient Coils Using a Patch Antenna Probe
As a part of this work a small patch antenna probe was developed to measure the variation in the electric field produced by gradient coils within an MRI in the presence of any active implantable medical devices (AIMDs). This probe was designed, fabricated, and tested within a gradient coil mimicking dB/dt exposure platform. A 2×1 cm small patch antenna followed by an instrumentational amplifier was chosen to measure the electric fields. Probe was fabricated using a 4-layer PCB. The fabricated probe was used to monitor the electric fields within the phantom in the gradient coil environment. To verify the observed behavior of the probe a simulation study was performed using Sim4Life. This study aims to assess the performance of this probe in a tissue mimicking environment within the coil.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信