{"title":"真空中静电触发的导线间电弧放电","authors":"H. Fujii, K. Kawabe","doi":"10.1109/DEIV.2006.357406","DOIUrl":null,"url":null,"abstract":"The anomaly of Japanese satellite ADEOS-II (Advanced Earth Observing Satellite II) appeared in 2003 was supposed to be caused by arcing discharges initiated due to ESD (electrostatic discharge) in the bundled wire-harnesses of the solar paddle. In order to make the condition of the occurrence of the discharge clear, it is necessary to evaluate the arcing discharge characteristics in vacuum quantitatively. Therefore we tried to investigate the characteristics of arcing discharge between two conductors consisting of a pair of wires for space use. The discharges were triggered by ESD released from a capacitor. These characteristics were obtained as parameters of the amplitude of the ESD, the pressure in the chamber and so on. We preliminarily obtained the result that the acing discharge time increased with increase of the amplitude of the ESD","PeriodicalId":369861,"journal":{"name":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ESD-Triggered Arcing Discharges between Wires in Vacuum\",\"authors\":\"H. Fujii, K. Kawabe\",\"doi\":\"10.1109/DEIV.2006.357406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The anomaly of Japanese satellite ADEOS-II (Advanced Earth Observing Satellite II) appeared in 2003 was supposed to be caused by arcing discharges initiated due to ESD (electrostatic discharge) in the bundled wire-harnesses of the solar paddle. In order to make the condition of the occurrence of the discharge clear, it is necessary to evaluate the arcing discharge characteristics in vacuum quantitatively. Therefore we tried to investigate the characteristics of arcing discharge between two conductors consisting of a pair of wires for space use. The discharges were triggered by ESD released from a capacitor. These characteristics were obtained as parameters of the amplitude of the ESD, the pressure in the chamber and so on. We preliminarily obtained the result that the acing discharge time increased with increase of the amplitude of the ESD\",\"PeriodicalId\":369861,\"journal\":{\"name\":\"2006 International Symposium on Discharges and Electrical Insulation in Vacuum\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 International Symposium on Discharges and Electrical Insulation in Vacuum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEIV.2006.357406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2006.357406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ESD-Triggered Arcing Discharges between Wires in Vacuum
The anomaly of Japanese satellite ADEOS-II (Advanced Earth Observing Satellite II) appeared in 2003 was supposed to be caused by arcing discharges initiated due to ESD (electrostatic discharge) in the bundled wire-harnesses of the solar paddle. In order to make the condition of the occurrence of the discharge clear, it is necessary to evaluate the arcing discharge characteristics in vacuum quantitatively. Therefore we tried to investigate the characteristics of arcing discharge between two conductors consisting of a pair of wires for space use. The discharges were triggered by ESD released from a capacitor. These characteristics were obtained as parameters of the amplitude of the ESD, the pressure in the chamber and so on. We preliminarily obtained the result that the acing discharge time increased with increase of the amplitude of the ESD