{"title":"功率控制电流源型PWM整流器的谐波功率抑制","authors":"T. Noguchi, K. Sano","doi":"10.1109/PEDS.2007.4487893","DOIUrl":null,"url":null,"abstract":"This paper focuses on specific harmonic active power suppression of a direct-power-controlled (DPC) PWM current-source rectifier (CSR) in order to achieve low distortion of the input line currents. Total input power factor of the DPC-based PWMCSR becomes worse as the load gets lower due to the low-order harmonics in the line currents, especially the fifth and the seventh. Since the dominant low-order harmonic currents cause an oscillation in the active power at frequency of sixth, suppression of the sixth-order harmonic active power is essential to improve the total power factor particularly in the low-load range. The paper describes a theoretical aspect and a suppression technique of the harmonic active power, followed by basic configuration and operation of the DPC-based PWMCSR. Effectiveness of the proposed technique is confirmed through computer simulations and experimental tests, using a 2-kW prototype. As a result, the total harmonic distortion of the line currents is effectively reduced by 10 %, which results in approximately 20-% improvement of the total input power factor at a 350-W load condition.","PeriodicalId":166704,"journal":{"name":"2007 7th International Conference on Power Electronics and Drive Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Specific Harmonic Power Suppression of Drector-Power-Controlled Current-Source PWM Rectifier\",\"authors\":\"T. Noguchi, K. Sano\",\"doi\":\"10.1109/PEDS.2007.4487893\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper focuses on specific harmonic active power suppression of a direct-power-controlled (DPC) PWM current-source rectifier (CSR) in order to achieve low distortion of the input line currents. Total input power factor of the DPC-based PWMCSR becomes worse as the load gets lower due to the low-order harmonics in the line currents, especially the fifth and the seventh. Since the dominant low-order harmonic currents cause an oscillation in the active power at frequency of sixth, suppression of the sixth-order harmonic active power is essential to improve the total power factor particularly in the low-load range. The paper describes a theoretical aspect and a suppression technique of the harmonic active power, followed by basic configuration and operation of the DPC-based PWMCSR. Effectiveness of the proposed technique is confirmed through computer simulations and experimental tests, using a 2-kW prototype. As a result, the total harmonic distortion of the line currents is effectively reduced by 10 %, which results in approximately 20-% improvement of the total input power factor at a 350-W load condition.\",\"PeriodicalId\":166704,\"journal\":{\"name\":\"2007 7th International Conference on Power Electronics and Drive Systems\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 7th International Conference on Power Electronics and Drive Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.2007.4487893\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th International Conference on Power Electronics and Drive Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2007.4487893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Specific Harmonic Power Suppression of Drector-Power-Controlled Current-Source PWM Rectifier
This paper focuses on specific harmonic active power suppression of a direct-power-controlled (DPC) PWM current-source rectifier (CSR) in order to achieve low distortion of the input line currents. Total input power factor of the DPC-based PWMCSR becomes worse as the load gets lower due to the low-order harmonics in the line currents, especially the fifth and the seventh. Since the dominant low-order harmonic currents cause an oscillation in the active power at frequency of sixth, suppression of the sixth-order harmonic active power is essential to improve the total power factor particularly in the low-load range. The paper describes a theoretical aspect and a suppression technique of the harmonic active power, followed by basic configuration and operation of the DPC-based PWMCSR. Effectiveness of the proposed technique is confirmed through computer simulations and experimental tests, using a 2-kW prototype. As a result, the total harmonic distortion of the line currents is effectively reduced by 10 %, which results in approximately 20-% improvement of the total input power factor at a 350-W load condition.